3

Set the sensitivity without object�

Press once

 

The yellow and green LEDs go out for approx� 1 s� 

 

>

After approx 3 s the green LED is on�

 

>

The unit is in the operating mode�

 

>

You can also proceed in reverse order: first setting without the object, then with 

the object�

* The sensitivity can also be set in exactly the same way using the programming 

wire (pin 2 / WH)� To activate the functions the programming wire is connected for the 

appropriate time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units� 

Feedback: If setting was not successful via the programming wire, the output will switch for 

2 s� The unit then reverts to the operating mode with the sensitivity unchanged�

If the setting of the sensitivity is not possible (e�g� object signal and 

background signal are about the same), the red LED flashes after step 3 

for approx� 2 s� The unit then passes into the operating mode with the 

sensitivity being unchanged� 

If the setting button is not activated for 15 minutes during the programming 

process, the unit passes automatically into the operating mode with the 

sensitivity being unchanged�

Setting of the sensitivity with moving objects*

1

Activate the programming mode of the unit�

 

Press for about 2 s  

 

until the red LED flashes�

The red LED goes out; the yellow and green LEDs flash alternately�

 

>

The unit is in the programming mode�

 

>

Summary of Contents for Efector200 OJ51 Series

Page 1: ...Operating instructions Through beam sensor OJ51xx 701398 01 07 2004 UK...

Page 2: ...supplied mounting fixture 4 Electrical connection 4 Setting of the sensitivity with stationary objects 5 Setting of the sensitivity with moving objects 6 Setting of the maximum sensitivity 7 Electron...

Page 3: ...ceiver transmitter receiver transmitter LED 1 push button 2 In the following sections installation and set up are described using the example of the type with front lens The functions of the units wit...

Page 4: ...e slot of the fixture until the spring clicks home To remove the unit press the spring down with a screwdriver and slide the unit out Electrical connection Isolate power Then connect the unit Programm...

Page 5: ...trast The following setting procedures should only be necessary in less straightforward applications for example if partly transparent objects must be detected Setting of the sensitivity with stationa...

Page 6: ...the output will switch for 2 s The unit then reverts to the operating mode with the sensitivity unchanged If the setting of the sensitivity is not possible e g object signal and background signal are...

Page 7: ...ck If setting was not successful via the programming wire the output will switch for 2 s The unit then reverts to the operating mode with the sensitivity unchanged If the setting of the sensitivity is...

Page 8: ...e versa The output function can be programmed in exactly the same way using the programming wire pin 2 WH To activate the functions the programming wire is connected for the appropriate time to L pin...

Reviews: