background image

Process and dialogue module ecomatDisplay CR1058, CR1059

10

4.2.2  Light sensor and status LED

The device is equipped with a light sensor� This sensor is used for automatic 

brightness adaptation of the display and the operating elements to the ambient 

brightness�

1

2

1:  Light sensor

2:  Status LED

 

Do not cover up the light sensor by construction measures�

The status LED shows the operating states of the device�

4.3  Panel mounting / control cabinet installation
4.3.1  Safety instructions for panel mounting / control cabinet installation

The indications for the operating temperature apply equally in front of and 

behind the installation level� 

The dimensions for the control panel cut-out are a basic prerequisite for the 

requirements concerning electrical protection, fire protection and protection 

rating of the device / system� However, this alone does not ensure 

compliance with the requirements� See the following safety instructions� The 

system creator has to take them into consideration for the risk assessment 

(→ 2)

Summary of Contents for ecomatDisplay CR1058

Page 1: ...Installation instructions Process and dialogue module ecomatDisplay CR1058 CR1059 80289590 00 09 2020 UK ...

Page 2: ...l mounting control cabinet installation 10 4 3 2 Integration with installation kit 12 4 3 3 Panel cut out 12 4 3 4 Mounting steps 13 4 4 Surface mounting with RAM Mount system 14 4 4 1 Mounting steps 15 4 5 Other installation types 15 5 Electrical connection 16 5 1 Wiring 16 5 2 Connection accessories 17 5 3 Connection technology 17 5 4 General wiring information 18 5 5 Operating voltage and fuses...

Page 3: ...7 8 1 Battery change 37 8 2 Cleaning the display surface 38 8 3 Cleaning the housing surface 39 8 4 Repair 39 8 5 Disposal 39 9 Approvals standards 39 This document is the original instructions Licences and trademarks All trademarks and company names used are subject to the copyright of the respective companies ...

Page 4: ...ction Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personal injury Slight reversible injuries may result NOTE Warning of damage to property ...

Page 5: ...t be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose 3 Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur In case of malfunctions please contact the manufacturer Tampering with the unit is not allowed Installa...

Page 6: ...h supply from SELV PELV in accordance with the technical data also in wet environments also outdoors if necessary with additional UV protection Communication with other system components e g decentralised I O modules is handled via CAN Ethernet and USB interfaces Together with the Linux operating system they form a universal platform for networking and communication with other CAN devices networks...

Page 7: ...ng system CAN interfaces with CANopen and SAE J1939 protocol Ethernet and USB interfaces 3 3 Distinctive features CR1058 CR1059 Touch screen Freely programmable backlit buttons 4 4 Navigation keys with button 1 1 Ethernet interfaces 1 1 CAN interfaces 2 4 ifm plug play CAN based 1 USB 2 0 interfaces 1 1 Analogue video inputs 2 Digital inputs BL 2 Digital outputs 2 5 A 2 Line In Speaker output 1 1 ...

Page 8: ... The system creator is responsible for ensuring compliance with the requirements concerning mounting of the device in the application with regard to shock vibration acceleration and weight The unit front withstands shock up to IK07 without damage NOTE Higher shock IK07 Damage possible Protection rating and electrical protection may be impaired The system creator has to protect the device depending...

Page 9: ... 30 1 1 4 x M5 threaded hole for RAM Mount system for the fixing profiles of the installation kit 2 pressure compensation element NOTE The device is equipped with a pressure compensation element Use of elastic materials to seal or close the associated ventilation ducts may cause damage to the device Do not use any sealing materials in the area around the pressure compensation elements ...

Page 10: ...vice 4 3 Panel mounting control cabinet installation 4 3 1 Safety instructions for panel mounting control cabinet installation The indications for the operating temperature apply equally in front of and behind the installation level The dimensions for the control panel cut out are a basic prerequisite for the requirements concerning electrical protection fire protection and protection rating of th...

Page 11: ...net the following requirements concerning fire protection apply When mounted in accordance with the information in chapter 4 3 the device itself meets the requirements of the IEC or DIN EN 61010 2 201 concerning a closed device with regard to protection against the spreading of fire WARNING The damping strip installation kit has no flammability rating and thus presents no fire obstacle Fire protec...

Page 12: ...gration with installation kit The installation kit enables horizontal vertical or overhead mounting of the device in a panel cutout This type of mounting is suited for materials with a thickness from 1 to 10 mm Longer set screws have to be used for material thicknesses 10 mm They are not supplied with the mounting accessories The fixing profile spacers M5 hexagon nuts washers M5 set screws and dam...

Page 13: ... of the spacers corresponds to the panel thickness If necessary use several spacers on top of each other Screw the fixing profile to the back of the device Tightening torque of the hexagon nuts 5 0 5 Nm NOTE Contact corrosion between the mounting screws and the housing Damage to the device Do not use copper or nickel plated materials for the bolting elements Use zinc plated screws In very corrosiv...

Page 14: ...ith the attached connector approx 72 mm 4 4 Surface mounting with RAM Mount system Using the RAM Mount components available as accessories the dialogue unit can be used as a firmly mounted desktop unit Two balls allow a variable orientation of the unit RAM Mount components 1 Mounting arm with fastening screw 2 Mounting plate with ball Dialogue module with mounted RAM Mount system You can find more...

Page 15: ...ording to RAM Mount indications 38 1 5 56 62 6 38 1 30 5 3 Mounting plate with ball Hole dimensions Tightening torque 5 0 5 Nm Slightly loosen the fastening screw of the mounting arm Place the mounting arm onto the balls and tighten the fastening screw 4 5 Other installation types Permissible installation types 4 3 Panel mounting control cabinet installation 4 4 Surface mounting with RAM Mount sys...

Page 16: ...e required separation from other circuits 5 1 Wiring Wiring 7 Technical data Only the signals indicated in the technical data or on the device label may be supplied to the terminals Unconnected connector pins need to have sealing of the individual cores NOTE Reverse polarity protection is not ensured in case of supply from the power supply SELV PELV to VBB30 and VBB0 Reverse polarity protection is...

Page 17: ...the M12 connector vertically so that the coupling nut will not damage the thread Unused sockets are equipped with protective caps included Tightening torque 1 3 0 1 Nm Use 40 pole connector with individually sealed cores to ensure protection rating IP 67 Only connect the connector when the supply voltage is disconnected No hot plugging is permitted Hot plugging is permitted at the USB type A conne...

Page 18: ... the device applies to the operating voltage connections A short circuit between operating voltage VBBX and USB audio video may cause damage to the device Lay supply and signal cables away from the device using the shortest possible route All connected cables must be provided with a strain relief Provide all outgoing cables with a strain relief 200 mm behind the cable entry Maximum cable lengths U...

Page 19: ... 116 89 97 110 8 16 V DC and 16 32 V DC 3 A Tfuse 120 s at max 6 25 A Terminal designation pursuant to DIN 72552 Supply cables of the inputs can be safeguarded together with the fuse for VBB15 NOTE Load dump and surge without connection of VBB0 Destruction of the device possible Always connect VBB0 even if the outputs are not used or are not available 5 6 Shield connection To ensure the protection...

Page 20: ...age category II They are construed as TNV 1 circuits Use a shielded CAT5 cable STP Shielded Twisted Pair to EIA TIA 568 Length max 25 m The max cable length depends for example on the bus topology the selected operating mode 10 100 Mbits s or the quality of the connectors Use screened connector housings and connect the screen of the Ethernet cable to the connector housing Do not lay the Ethernet c...

Page 21: ...l panel or in the dashboard 3 USB device Permanent connection Dialogue module USB connector Use prewired cable M12 connector B coded on USB socket type A watertight cable length 1 5 m wires twisted and screened Use only cables to USB 2 0 specification for individual wiring Keep length B as short as possible and position the USB connector in immediate vicinity to the dialogue module Length B consid...

Page 22: ...eakers For an optimum audio output 8 Ω loudspeakers have to be used 6 Set up 6 1 General The factory setting of the device shows a demo application By means of the installed recovery app any suitable firmware version can be loaded to the device Factory settings IP adress 192 168 82 247 Subnet mask 255 255 255 0 Gateway IP address 192 168 82 1 The user is responsible for the safe function of the ap...

Page 23: ... allows the setting of the device parameters directly via the local display or the web interface of the device Local set up is started by selecting the set up button in the App Launcher While the App Launcher is shown entering the device IP address e g 192 168 82 247 via the connected web browser takes you to the web set up After leaving the set up a project can be loaded Libraries lib are availab...

Page 24: ...ause considerable heating up The device temperature must not exceed the maximum permissible value 7 Technical data The value provided by the internal temperature sensor can e g be used for the following actions Reducing the display brightness the self heating will decrease Warning the operator about the heating and an upcoming switch off of the display Switch off of the display NOTE Internal tempe...

Page 25: ...ass chemically hardened and anti reflective Colours 262144 18 bits Background illumination LED life cycle 50 000 h Brightness 600 cd m can be set to 0 100 step increment 1 Contrast ratio typical 500 1 Character sets can be uploaded individually and are freely scalable preinstalled ifm ISO fonts with vehicle specific symbols Arial Courier Mechanical data Mounting variants panel mounting control panel...

Page 26: ...tection yes in case of supply via the on board system battery Power consumption 19 W Current consumption VBB0 5 A Processor ARM dual core 64 bits 800 MHz with GPU Memory total 1 GByte RAM 2 GBytes flash non volatile memory 16 kB Interfaces CAN0 1 CAN interface 2 0 A B ISO 11898 20 Kbits s 1 Mbit s default 250 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J 1939 or free protoc...

Page 27: ...must not exceed 72 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery buffered CR1225 3 V 48 mAh Status LED RGB LED colours and states programmable by means of the application software Operating states factory setting Colour Status Description off no operating voltage green 5 Hz l...

Page 28: ... valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 Ω 4 kV contact discharge function state A 6 kV contact discharge function state C 8 kV air discharge function state C Climatic tests EN 60068 2 30 Damp heat cyclic Upper temperature 55 C number of cycles 6 EN 60068 2 78 Damp h...

Page 29: ...prior notice 17 09 2020 CR1058 page 5 CR1058 Technical data Control systems Back of the unit 1 2 3 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector 5 poles 4 M12 connector 4 poles AMP connector 40 poles 116 121 114 118 117 119 113 105 97 89 106 98 90 82 M12 connector 3 4 socket B coded 5 poles socket D coded 4 poles 3 1 2 4 ...

Page 30: ... connected SERVICE1 not connected not connected CAN0_H CAN1_H not connected not connected not connected SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 not connected not connected not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L not connected not connected not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L 114 115 1...

Page 31: ...ation in wet conditions or with gloves Format 16 10 109 x 65 8 mm 5 diagonal Resolution 800 x 480 pixels Orientation horizontal vertical Surface glass chemically hardened and anti reflective Colours 262144 18 bits Background illumination LED life cycle 50 000 h Brightness 600 cd m can be set to 0 100 step increment 1 Contrast ratio typical 500 1 Character sets can be uploaded individually and are f...

Page 32: ...its s 1 Mbit s default 250 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J 1939 or free protocol Raw CAN ETH0 transmission rate 10 100 Mbits s protocols TCP IP UDP Modbus TCP OPC UA Micro Embedded Device Server EtherNet IP scanner adapter USB0 USB 2 0 high speed transmission rate up to 480 Mbits s USB master operation output current per interface 500 mA Analogue video input ...

Page 33: ...must not exceed 85 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery buffered CR1225 3 V 48 mAh Status LED RGB LED colours and states programmable by means of the application software Operating states factory setting Colour Status Description off no operating voltage green 5 Hz l...

Page 34: ... valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 Ω 4 kV contact discharge function state A 6 kV contact discharge function state C 8 kV air discharge function state C Climatic tests EN 60068 2 30 Damp heat cyclic Upper temperature 55 C number of cycles 6 EN 60068 2 78 Damp h...

Page 35: ...prior notice 17 09 2020 CR1059 page 5 CR1059 Technical data Control systems Back of the unit 1 2 3 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector 5 poles 4 M12 connector 4 poles AMP connector 40 poles 116 121 114 118 117 119 113 105 97 89 106 98 90 82 M12 connector 3 4 socket B coded 5 poles socket D coded 4 poles 3 1 2 4 ...

Page 36: ...M0 CAN0_L CAN1_L CAN2_L CAN3_L not connected SERVICE1 not connected IFM0 CAN0_H CAN1_H CAN2_H CAN3_H not connected SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 VIDEO0_GND VIDEO1_GND not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L VIDEO0_SIGNAL VIDEO1_SIGNAL not connected not connected not connected not connected AUDIO_OUT_R AUDIO_OUT_L 114 ...

Page 37: ... 8 Maintenance repair and disposal 8 1 Battery change Battery change only be qualified personnel Before changing the battery fully separate the device from supply voltage 1 2 1 Service cover 2 Battery Replace battery when time is permanently wrong after switch on ...

Page 38: ...sealing areas and sealing for soiling and clean if necessary Screw on service cover until end stop is reached to restore protection rating Reset system time via device set up or application see programming manual ecomatDisplay Disposal of used batteries 8 5 Disposal 8 2 Cleaning the display surface Unsuitable cleaning agents and chemicals can damage the display surface The following agents are not...

Page 39: ...y be repaired by the manufacturer Observe the safety instructions 2 Safety instructions 8 5 Disposal Dispose of used batteries in accordance with the national environmental regulations Do not dispose of used batteries with household waste Dispose of the device in accordance with the national environmental regulations 9 Approvals standards Test standards and regulations 7 Technical data The EC decl...