Presetting
Programming
The following parameters can be set (3rd column: basic setting):
1
2
3
Press briefly.
Actual value is displayed,
first decade is flashing.
The active decade is flashing.
Press briefly
when last decade is flashing
(= terminating entry).
The new value is displayed.
Press this key to increment
in active decade.
Press this key to change
from one decade to the
other.
P01
counting function
0 = VRD (up / down differential; electronic and mechanical
pulse pick-ups)
1 = VR (up / down; incremental shaft encoders)
1
P02
control inputs for electronic or mechanical pulse pick-ups
0 = pnp switching
1 = npn switching
0
decimal places
0 ... 3 = 0 ...3 decimal places after the point
P03
0
0
last value memory
0 = last value memory active
(on power up the last value is displayed)
1 = last value memory not active
(on power up the preset value is displayed)
P04
P05
front reset
0 = front reset active
1 = front reset not active
0