Error tables
Error flags .......................................................................................................................................... 190
Errors: CAN / CANopen .................................................................................................................... 190
19606
>
7.3.1
Error flags
19608
→ chapter
System flags
(
>
7.3.2
Errors: CAN / CANopen
19610
19604
→ System manual "Know-How ecomat
mobile
"
→ chapter
CAN / CANopen: errors and error handling
>
EMCY codes: CANx
13094
The indications for CANx also apply to each of the CAN interfaces.
EMCY code
object 0x1003
Object
0x1001
Manufactor specific information
Byte 0
[hex]
Byte 1
[hex]
Byte 2
[hex]
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Description
00
80
11
--
--
--
--
--
CANx monitoring SYNC error (only slave)
00
81
11
--
--
--
--
--
CANx warning threshold (> 96)
10
81
11
--
--
--
--
--
CANx receive buffer overrun
11
81
11
--
--
--
--
--
CANx transmit buffer overrun
30
81
11
--
--
--
--
--
CANx guard/heartbeat error (only slave)
>
EMCY codes: I/Os, system
2671
The following EMCY messages are sent automatically in the following cases:
• as CANopen master: if
CANx_MASTER_EMCY_HANDLER
(
) is called cyclically
• as CANopen slave: if
CANx_SLAVE_EMCY_HANDLER
(
) is called cyclically
EMCY code
object 0x1003
Object
0x1001
Manufactor specific information
Byte 0
[hex]
Byte 1
[hex]
Byte 2
[hex]
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Description
00
21
03
I0
Diagnosis analogue current inputs
00
31
05
Terminal voltage VBBo/VBBs
00
61
11
Memory error
Summary of Contents for Ecomat 100 Mobile CR0301