6 Electrical connection
The unit must be connected by a qualified electrician�
The national and international regulations for the installation of electrical
equipment must be adhered to�
Voltage supply according to EN 50178, SELV, PELV�
►
Disconnect power�
►
Connect the unit as follows:
Core colours
1
1
1
3
4
2
5
1
E434xx
EVC843
3
4
2
5
5 2 4 3
BN
2
WH
4
BK
3
BU
1
3
4
A
2
BK
black
BN
brown
BU
blue
WH
white
GY
grey
Connections
(1): to the master
(2): to the Y cable
(3): to the IO-Link
device
(4): to the
installation
(A): electrical separation
Connection of the data splitter E434xx:
4
3
2
1
to the master (1)
1: L+ (from the master)
2: not connected
3: L- (from the master)
4: C: IO-Link
3
1
2
4
5
to the Y cable (2)
1: L+ (from the installation)
2: C/Q: IO-Link
3: L- (from the installation)
4: switching output OUT1 / IO-Link
1)
PNP (E43406) or NPN (E43410)
5: not connected