20
4.3.5. Example 5: Display QR-Code
1.
Define the QR-Code’s text (Index 830
→
3.8).
2.
In order to display the QR-Code on the display
set the layout to 21 during run time (Byte 13
→
4.1).
5.
Technical data
Technical data and scale drawing at www.ifm.com.
5.1.
Identification parameters
These parameters contain the identification data of the IO-Link device.
Name
Index /
subind
ex
Type /
length
Content
Vendor name
16/0
String/19
ifm electronic gmbh
Vendor text
17/0
String/11
www.ifm.com
Product name
18/0
String [9
E30391_AB
Product ID
19/0
String/6
E30391
Product text
20/0
String/15
IO-Link Display
Serial number
21/0
String/12
Unique device identification
Hardware version
22/0
String/2
Hardware version
Software Version
23/0
String/5
Software Version
User-specific
marking
24/0
String/32
Free text of measuring
point or device