3  Functions and features

The unit is used for the visual display of machine conditions� The versions DV2130 

and DV2131 additionally have a buzzer for acoustic signalling� The versions 

DV2121 and DV2131 additionally have a feedback button�
The LED segment and the audible warning device can be switched on and off 

individually�

 

The device is intended for indoor use only� 

Observe the operating conditions 

(→ 10 Technical data)

 

The unit must not be used for safety-related applications such as 

access control�

The units can be controlled and configured via the standardised IO-Link interface�

3.1  IO-Link
3.1.1  General information

This unit has an IO-Link communication interface which enables direct access to 

process and diagnostic data� In addition it is possible to set the parameters of the 

unit while it is in operation� Operation of the unit via an IO-Link interface requires 

an IO-Link capable module (IO-Link master).

3.1.2  Device-specific information

With a PC, suitable IO-Link software and an IO-Link adapter cable, communication 

is possible while the system is not in operation� The IODDs necessary for the 

configuration of the unit, detailed information about process data structure, 

diagnostic information, parameter addresses and the necessary information about 

the required IO-Link hardware and software can be found at www�ifm�com�

Summary of Contents for DV2120

Page 1: ...Operating instructions 1 segment signal lamp DV2120 DV2121 DV2130 DV2131 80284259 00 12 2019 P_MZ_e200_0102 UK...

Page 2: ...nnection 7 5 2 Pin connection 7 5 2 1 IO Link mode 7 5 2 2 Standard mode 7 6 Operating and display elements 8 7 Operation 8 7 1 IO Link 8 7 1 1 General 8 7 1 2 On off mode 9 7 1 3 RGB mode 9 7 2 Opera...

Page 3: ...reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used WARNING Warning of serious personal injury Death or serious irreversi...

Page 4: ...during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose 3 Fu...

Page 5: ...d IO Link interface 3 1 IO Link 3 1 1 General information This unit has an IO Link communication interface which enables direct access to process and diagnostic data In addition it is possible to set...

Page 6: ...ate a mounting section 31 mm Only mount the unit in upright position using the supplied M30 nut Tightening torque 4 5 Nm Special accessories are available to allow mounting the unit using a mounting t...

Page 7: ...tor of the unit Tightening torque max 0 4 Nm Observe the maximum tightening torque of the connection cable 5 1 IO Link connection The IO Link port must be connected according to the IO Link specificat...

Page 8: ...Link 7 1 1 General Connect the unit to an IO Link master A port using a 5 pole connection cable The controller switches the LED segment on and off in the configured colours according to the set param...

Page 9: ...ash rate slow medium fast high flash rate slow medium fast Brightness 0 100 For the models with an acoustic signal device the audibility of the buzzer can be set 7 6 5 4 3 2 1 0 PDOut LED c LED b LED...

Page 10: ...ed 0 0 1 0 green 0 0 1 1 orange 0 1 0 0 blue 0 1 0 1 violet 0 1 1 0 turquoise 0 1 1 1 white 1 0 0 0 yellow Byte 0 Bit 6 Byte 0 Bit 5 Byte 0 Bit 4 Frequency 0 0 0 permanently on 0 0 1 low flash rate sl...

Page 11: ...alternating fast 2450 Hz and 3080 Hz 4 0 1 1 rising from 1000 Hz to 4000 Hz falling to 1000 Hz 5 1 0 0 continuous note 2450 Hz interrupted every 500 ms 6 1 0 1 pulsating fast 2450 Hz interrupted every...

Page 12: ...d the signal lamp glows with the corresponding colour and flashing frequency Example Input 1 red flashing fast 100 Input 2 yellow permanently on 100 Input 3 green permanently on 100 This is how this s...

Page 13: ...l lamp glows blue Inputs 1 and 3 triggered The signal lamp glows purple Depending on the product version the IO Link port is used as an input for the buzzer of as an output for the feedback button For...

Page 14: ...Frame Size 80 mm x 40 5 mm P_MZ_e200_0103 M12x1 61 10 20 16 2 M30x1 5 56 M12x1 61 10 20 16 2 M30x1 5 56 Dimensions mm 9 2 DV213x Original Scale Drawing MTD EPS Source Product Scale Drawing Frame Size...

Page 15: ...temperature C 25 50 Storage temperature C 40 75 Max permissible relative air humidity 90 Maximum operating altitude m 4000 above sea level IO Link Connectors M12 connector 5 poles Weight 85 100 10 1 I...

Page 16: ...h the applicable national regulations 11 1 Cleaning the housing surface Disconnect the device Clean the device from dirt using a soft chemically untreated and dry cloth In case of heavy dirt use a dam...

Reviews: