12
Plug
Terminal Connection
A2
L-
Supply voltage (GND)
directly connected to the device ground
S44
Sensor 2 supply (+ 24 V DC)
S45
Sensor 2 GND (0 V DC)
S43
Sensor 2 input
A3
13
Current path 1A (relay contacts)
(not connected)
(not connected)
14
Current path 1B (relay contacts)
C1
Y3
Deactivation of the monitoring function (P)
Y4
Deactivation of the monitoring function (N)
Y5
Automatic mode selection
Y6
Manual mode selection
C2
Y7
Transistor output "Fault"
Y8
Transistor output "Overspeed"
Y1
Feedback circuit output
Y2
Feedback circuit input
C3
23
Current path 2A (relay contacts)
(not connected)
(not connected)
24
Current path 2B (relay contacts)
Observe the technical data of the electrical connections�
PELV power supplies are to be used according to EN 60204-1�
The electrical input signals meet the requirements to EN 61131, type 2�
Do not use unconnected terminals as support point terminal�
Terminal tightening torque: 0�6���0�7
Nm (5���7
lb-in)�