13
UK
►
Unused sockets are equipped with protective caps (included)� Tightening
torque: 0�8
±0�1
Nm
►
Use 81-pole connectors with individually sealed cores to ensure protection
rating IP 67�
Only connect the 81-pole connectors when the supply voltage is
disconnected� No "hot plugging" is permitted�
The ingress resistance of cables which the users have cut to length
themselves has to be ensured�
►
Use twisted-pair cables for the CAN connection�
►
Use a min� category 5 (Cat 5) cable for the Ethernet connection�
The RS-232 interface serves only as a service interface (e�g� for firmware
updates)�
►
Provide all outgoing cables with a strain relief 200 mm behind the cable entry�
6.3 Shield connection
EPS Source
Product Scale Drawing
Frame Size: ⁸⁰ mm x ⁴⁹,⁵ mm
Original Scale Drawing (MTD)
P_MZ_e100_0093
Scale: 1:2
¹⁸
⁴⁷
²⁰⁶
²¹⁹
²⁵⁰
²⁷¹
6,4
M¹²x¹
LEDs
¹
²
1: Holes for shield connection
To ensure the protection of the device against electrical interference and to
ensure the safe function of the device, the housing has to be connected to
the body / GND of the supply using the shortest possible route�
Otherwise the safety function is not ensured!
►
Connect the device to the ground of the vehicle using the M4 self-tapping
screw (included)�