Provide all outgoing cables with a strain relief 200 mm behind the cable
entry�
6 Electrical connection
►
Disconnect the machine from the mains supply before installation; if
necessary, also disconnect any independently supplied input / output
load circuits�
►
Observe the national and international regulations for the installation of
electrical equipment�
►
Observe the requirements according to the standard EN 60204�
Accessible surfaces of the device are insulated from the circuits with basic
insulation to IEC 61010-1 (secondary circuit with max� 32 V DC, supplied from the
mains circuit up to 300 V of overvoltage category II)�
GND of the supply is connected via EMC suppression capacitors on the shield
connection (metal housing) of the device�
The external wiring has to be carried out in a way that ensures the required
separation from other circuits�
6.1 Wiring
The connection terminals may only be supplied with the signals indicated in
the technical data / on the device label and only the approved accessories
from ifm may be connected�
Only connect the connector pins as shown in the pin layout� Unspecified
connector pins remain unconnected� The unconnected connector pins need
to have sealing of the individual cores�