11 Object directory
11.1 Manufacturer Specific Profile Area; index 2000 to 5FFF
Index S-Idx
Designation
Type
Default Description
2000
0
I/O
Configuration u8, ro
0x04
Number of the entries
= number of the output channels
2000
1
Output
channel
1+2 *)
u8, rw
0x02
configuration channel pair 1/2 *)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
2000
2
Output
channel
3+4 *)
u8, rw
0x02
configuration channel pair 3/4 *)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
2000
3
Output
channel
5+6 *)
u8, rw
0x02
configuration channel pair 5/6 *)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
2000
4
Output
channel
7+8 *)
u8, rw
0x02
configuration channel pair 7/8 *)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
2001
0
PWM
Frequency
u8, rw
0x64
(100 Hz)
Setting in Hz
Range = 20 Hz to 150 Hz
Values below 20 Hz or above 150 Hz are not
accepted� The existing value remains valid�
2002
0
Actual Current
Values
u8, ro
0x04
Number of the entries
= number of the measuring channels of current
2002
1
Actual Current
Value
Channel 1/2
u8, ro
Current values in mA
2002
2
Actual Current
Value
Channel 3/4
u8, ro
Current values in mA
2002
3
Actual Current
Value
Channel 5/6
u8, ro
Current values in mA
2002
4
Actual Current
Value
Channel 7/8
u8, ro
Current values in mA