139
ifm
Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
J1939_STATUS
7670
Unit type = function block (FB)
Unit is contained in the library
ifm_J1939_NT_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
7672
Via J1939_STATUS, relevant information can be read back to the J1939 stack.
>
Parameters of the inputs
7673
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
execute this function element
FALSE:
unit is not executed
> Function block inputs are not active
> Function block outputs are not specified
CHANNEL
BYTE
CAN interface (1...n) depending on the device
>
Parameters of the outputs
7674
Parameter
Data type
Description
SA
BYTE
claimed source address
CYCLIC
WORD
number of the cyclic messages
TIMEOUT
BYTE
source address of the node which did not provided data for the
process image in due time
255 = 0xFF = all nodes sent the data in due time
VERSION
DWORD
Version of the
ifm
CAN stack library
RESULT
BYTE
feedback of the function block
(possible messages → following table)
Possible results for RESULT:
Value
dec | hex
Description
0
00
FB is inactive
1
01
Protocol is active
2
02
Protocol is not active
3
03
Source address requested
4
04
Address lost
242
F2
Error: setting is not possible