background image

Ethernet switch

AL3051

9

6.3 Ethernet

The Ethernet devices are connected via the Ethernet ports.

The ports can be used by the Ethernet devices as required.

Connecting the Ethernet ports to each other will cause the device to fail.

u

Do not connect the Ethernet ports of the device to each other.

Wiring:

1

2

3

4

5

1: TX +
2: RX +
3: TX -
4: RX -
5: not used

u

Connect Ethernet devices to the ports X01...X06.

u

For connection, use an M12 connector (with at least protection rating: IP 65 / IP 66 / IP 67 / IP
69K). Max. cable length: 100 m.

6.4 Ground connection

The FE potential is connected to the following points of the device:

Upper mounting lug of the housing

u

Ground the device via the mounting screw of the upper mounting lug.

u

To ensure the protection of the device against electrical interference and to ensure the safe
function of the device, the housing has to be connected to ground of the supply using the
shortest possible route.

6.5 Voltage supply

The device is connected to the supply voltage US via the power IN port. The supply voltage US
supplies the device with voltage.

Max. current consumption: 100 mA (12 V) / 50 mA (24 V)

Port X31 has overvoltage protection (US).

The port X31 has reverse polarity protection (US).

The port X31 has an inrush current limitation (max. current: 3 A).

ATTENTION

Current surge with high voltage input due to disconnection of the device from battery supply
while the engine is running

w

Damage to the device

u

When supplied by the on-board system in vehicles, do not disconnect the device from
the battery when the engine is running.

Wiring:

4

3

2

1

1: + 24 V DC (US)
2: not used
3: GND (US)
4: not used

u

Disconnect power.

u

Connect the device via port X31 to 12 / 24 V DC (8…32 V SELV according to DIN 60950).

Summary of Contents for AL3051

Page 1: ...Operating instructions Ethernet switch AL3051 11392989 01 06 2023 GB...

Page 2: ...stallation 7 5 1 Overview 7 5 2 Install device 7 6 Electrical connection 8 6 1 Overview 8 6 2 General wiring information 8 6 2 1 Connection technology 8 6 3 Ethernet 9 6 4 Ground connection 9 6 5 Volt...

Page 3: ...at documentation ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or...

Page 4: ...ct of the system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental condition...

Page 5: ...is used for networking of up to 6 Ethernet devices The device is designed for use in Ethernet networks The device is designed for use without a control cabinet in the food industry The device is desi...

Page 6: ...name Reset device MAC address table Capacitance 2000 entries MAC Aging Time 200 400 s Quality of Service IEEE 802 1p IEEE 802 1Q Priority queues 4 4 2 Ethernet ports Supported transmission standards...

Page 7: ...e u Disconnect the power of the machine before installation u Use a flat mounting surface for installation u Observe the maximum tightening torque u Fasten the module onto the mounting surface using t...

Page 8: ...n according to EN61010 1 They are designed for network environment 0 according to IEC TR62102 6 2 1 Connection technology The M12 connection parts in the device comply with the ingress resistance requ...

Page 9: ...nst electrical interference and to ensure the safe function of the device the housing has to be connected to ground of the supply using the shortest possible route 6 5 Voltage supply The device is con...

Page 10: ...L3051 Ethernet switch 10 u For UL applications Connect the device via port X31 to 24 V DC 8 28 V SELV PELV u For connection use an M12 connector with at least protection rating IP 65 IP 66 IP 67 IP 69...

Page 11: ...NK ACT port X01 7 1 1 Voltage supply LED Description Colour State Description US Voltage supply status Green Off No supply voltage is applied or the applied supply voltage is too low On Supply voltage...

Page 12: ...up u Install the device correctly u Establish a correct electrical connection with the device w Once connected to the supply voltage the device will start w The LEDs show the status of the device w T...

Page 13: ...endly way in accordance with the applicable national regulations 9 1 Cleaning the housing surface Clean the surface of the device when necessary u Disconnect the device from the supply voltage u Clean...

Reviews: