SmartPLC SafeLine with PROFIBUS slave interface
131
7.7.5
Safety: System
42256
The [System] menu page provides access to status information of the fail-safe PLC of AC412S.
>
Display status information of the fail-safe PLC
42227
To display status information of the fail-safe PLC:
1 Select menu page
►
>
2 Display status information of the fail-safe PLC
>
Menu page shows the following information:
Name
Description
Possible values
[F PLC firmware]
Firmware version of the fail-safe
PLC
e.g. Rel:(1)01.00.243
[Safety PLC status]
Status of the fail-safe PLC
Invalid
Invalid state
Safe started
Safety module correctly started
No application
No safe configuration available
IEC task enabled
Safe IEC task enabled
IEC task started
Safe IEC task started
IEC error
Error in the safe IEC task
RUN (debug)
Safe application in the RUN mode
(debug operation)
STOP (debug)
Safe application in the STOP mode
(debug operation)
RUN (safe)
Safe application in the RUN mode (safe
operation)
CODESYS error
Fail-safe PLC in the safe error state
Hardware error
Error in the hardware of AC412S