28
8.4 Extended functions – Min/max memory – Emtpy pipe –
Simulation
↑ Main menu
MEM
EF
EPD
SIM
8.1
* Parameters are only displayed for the selection EP�On = On�
Page 1: ...Operating instructions Magnetic inductive flow meter SM9000 SM9100 SM2000 SM2100 706222B2 00 01 2013 UK...
Page 2: ...monitoring with preset counter 9 4 5 Temperature monitoring 9 4 6 Empty pipe detection 9 4 7 Volumetric flow or temperature monitoring switching function 10 4 7 1 Hysteresis function 11 4 7 2 Window...
Page 3: ...pulse value 33 10 3 Settings for consumed quantity monitoring 33 10 3 1 Settings for limit value monitoring with OUT1 33 10 3 2 Settings for limit value monitoring with OUT2 33 10 3 3 Setting the anal...
Page 4: ...ured value damping 36 10 6 7 Setting the error behaviour of the outputs 37 10 6 8 Configuring the empty pipe detection as diagnostic output 37 10 6 9 Activating deactivating empty pipe detection 37 10...
Page 5: ...ctrical connec tion set up operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator Check the compatibility of the product materials see...
Page 6: ...nction 4 1 Measuring principle for volumetric flow monitoring The magnetic inductive measuring principle means that a magnetic field is gener ated in the measuring pipe via current carrying coils When...
Page 7: ...s 10 3 2 or switching signal for temperature limit value 10 5 1 or analogue signal for volumetric flow quantity 10 3 3 or analogue signal for temperature 10 5 2 or input for external reset signal InD...
Page 8: ...to the current consumed quantity since the last reset The quantity meter takes account of the flow direction for totalisation Flow according to the marked flow direction arrow flow direction meter ad...
Page 9: ...s reached during t output 1 switches and remains switched until the meter is reset If the quantity x is not reached during the time t the meter is automatically reset and counting starts again output...
Page 10: ...set as time depending or not time depending 10 6 10 4 7 Volumetric flow or temperature monitoring switching function OUTx changes its switching state if it is above or below the set switching limits...
Page 11: ...ion Normally open OUx Fno Normally closed OUx Fnc The width of the window can be set by means of the difference between SPx and rPx SPx upper value rPx lower value Example of volumetric flow monitorin...
Page 12: ...ansmitted in an analogue way is therefore below the display range 9 Curve of the analogue signal at factory setting 10 Curve of the analogue signal with shifted ASP and AEP 11 The process value transm...
Page 13: ...ue way is below the display range 8 Curve of the analogue signal at factory setting 9 Curve of the analogue signal with shifted ASP and AEP 10 The process value transmitted in an analogue way is there...
Page 14: ...in the error state FOU ON FrEP configured frequency at FEP 10 3 4 Setting the frequency value for volumetric flow 4 10 Start up delay The start up delay dST influences the switching outputs of the vo...
Page 15: ...Volumetric flow quantity falls below 0 5 within dST Outputs are reset at once dST is stopped Example dST for hysteresis function 1 Volumetric flow quantity Q reaches 0 5 of VMR dST starts output beco...
Page 16: ...this function small volumetric flow quantities can be ignored 10 6 12 Flows below the LFC value are evaluated by the sensor as standstill Q 0 4 12 Simulation With this function small volumetric flow...
Page 17: ...n F 1 Install the unit so that the measuring pipe is completely filled Arrange for inlet and outlet pipe lengths Disturbances caused by bends valves reductions etc are compensated for It applies in pa...
Page 18: ...18 Install in front of or in a rising pipe F F 4 F 5 F flow direction With empty pipe detection Install the unit according to figure 1 4 or 5...
Page 19: ...he suction side of a pump Directly in front of the spout of the pipe At the highest point of the pipe system F F F F F F flow direction The unit can be installed independently of the orientation if th...
Page 20: ...er B into the pipe A 2 Place the seals C and install the unit according to the marked flow direction 3 Screw the adapter B with the threads D until it is hand tight 4 Tighten the two adapters in oppos...
Page 21: ...limit values for volumetric flow Pulse signal 1 pulse every time the defined volumetric flow quantity is reached Switching signal quantity meter reached preset value Frequency signal for volumetric fl...
Page 22: ...ith setting SELd FLOW Meter reading of the totaliser with setting SELd TOTL Current medium temperature with setting SELd TEMP Parameters and parameter values 10 Enter button Selecting the parameters R...
Page 23: ...23 UK 8 Menu 8 1 Process value display l min C m3 h l m3 l m3 Stored totaliser value Main menu...
Page 24: ...24 8 2 Main menu Process value display Extended functions The parameters are only displayed when selected at OU1 The parameters are only displayed when selected at OU2...
Page 25: ...lternative configure OUT2 Pin2 as input for external reset signal Setting OU2 In D Hno Hysteresis normally open Hnc Hysteresis normally closed Fno Window normally open Fnc Window normally closed ImP P...
Page 26: ...26 8 3 Extended functions Basic settings Main menu CFG EF 8 1 The parameters are only displayed when selected at OU1 The parameters are only displayed when selected at OU2...
Page 27: ...ut 2 in case of an error dST Start up delay of volumetric flow monitoring P n Output logic pnp npn dAP Measured value damping damping constant in seconds diS Update rate and orientation of the display...
Page 28: ...28 8 4 Extended functions Min max memory Emtpy pipe Simulation Main menu MEM EF EPD SIM 8 1 8 1 Parameters are only displayed for the selection EP On On...
Page 29: ...SIM Submenu simulation 8 4 2 Submenu min max memory MEM HI F Max value flow LO F Min value flow HI T Max value temperature LO T Min value temperature 8 4 3 Submenu empty pipe EPD EP On Empty pipe dete...
Page 30: ...setting Parameters can be set before installation and set up of the unit or during opera tion If you change parameters during operation this will influence the function Ensure that there will be no m...
Page 31: ...4 5 3 Confirm the parameter value 6 Press Enter briefly The parameter is displayed again The new setting value is saved 6 Finish parameter setting and change to the process value display Wait for 30 s...
Page 32: ...ocking The unit can be locked electronically to prevent unintentional settings Setting at the factory not locked Locking is also possible via an IO Link capable parameter setting tool Locking Make sur...
Page 33: ...et the value at which the output switches Select rP1 and set the value at which the output switches off 10 3 2 Settings for limit value monitoring with OUT2 Select SEL2 and set FLOW Select OU2 and set...
Page 34: ...set in ImPS is reached 10 4 2 Settings for quantity monitoring via the preset counter Select OU1 and set ImP Select ImPS and set the volumetric flow quantity at which output 1 switches Select ImPR and...
Page 35: ...Select rP2 and set the value at which the output switches off 10 5 2 Setting the analogue value for temperature Select SEL2 and set TEMP Select OU2 and set the function I temperature proportional cur...
Page 36: ...he measured values every 200 ms d3 update of the measured values every 600 ms rd1 rd2 rd3 display as for d1 d2 d3 rotated by 180 OFF the display is switched off in the operating mode 10 6 3 Changing t...
Page 37: ...ve of the error as defined with the parameters The analogue signal corresponds to the measured value 10 6 8 Configuring the empty pipe detection as diagnostic output Select OU1 or OU2 and set dOU Sele...
Page 38: ...F or LO F HI F max value LO F min value Delete memory Select HI F or LO F Press Enter briefly Keep or pressed is displayed Press Enter briefly It makes sense to delete the memories as soon as the unit...
Page 39: ...arts The values are simulated for the time set at S Tim SIM is displayed simultaneously with the process values Cancel with Enter OFF The simulation is not active 10 7 4 Resetting all parameters to fa...
Page 40: ...display is lit and the current process value is displayed After 30 seconds the display changes to the standard display LED Process value display Unit 1 Current flow volume per minute l min 2 Current f...
Page 41: ...parameter is displayed 2 1 Display the parameter value 3 Press Enter briefly The currently set value is displayed for 30 s By pressing Enter briefly several times the display switches between paramete...
Page 42: ...ion zone of volumetric flow or temperature Err Unit faulty malfunction Measured value outside the detection zone C Loc Setting pushbuttons locked parameter change rejected Active IO Link communication...
Page 43: ...0 rP1 19 5 ImPS 0 1 ImPR YES OU1 Hno OU2 I SP2 FLOW 40 rP2 FLOW 39 5 SP2 TEMP 20 C rP2 TEMP 19 6 C ASP FLOW 0 AEP FLOW 100 ASP TEMP 20 C AEP TEMP 80 C FEP 100 FrEP 1 kHz FDir FPro LFC 5 l min D In2 ED...
Page 44: ...44 Uni Lmin SELd FLOW SEL2 FLOW EP On OFF dEP E 0 s dEP F 2 s S FLW 20 S TMP 20 C S Tim 2 min of VMR More information at www ifm com...