6 Technical data
Operating voltage [V] ..........................................................................................
9.6...32 DC
Current rating [mA]
.........................................................................................................500
Current consumption [mA]
.............................................................................................< 25
Switching frequency [Hz]
................................................................................................100
Setting accuracy [% of the end value of the measuring range]
.................................< ± 2.5
Characteristics deviation
[% of the end value of the measuring range]
...........................< ± 1.5 (BFSL) / < ± 2.5 (LS)
Repeatability [% of the end value of the measuring range]
.......................................< ± 0.5
Temperature drift [% of the end value of the measuring range/10 K]
........................< ± 0.5
in the temperature range [°C]
......................................................................................0...80
Operating temperatur [°C]
........................................................................................-25...80
Medium temperature [°C]
.........................................................................................-25...80
Protection ...............................................................................................................
IP 67 / III
Insulation resistance [M
Ω
] .......................................................................
> 100 (500 V DC)
Shock resistance [g] ..............................................................
50 (DIN / IEC 68-2-27, 11ms)
Vibration resistance [g] ................................................
20 (DIN / IEC 68-2-6, 10 - 2000 Hz)
Housing material
..................
Pocan; PC (Macrolon); FPM (Viton); stainless steel (316S12)
Materials (wetted parts) ....................................
stainless steel (316S12); seal: FPM (Viton)
EMC
EN 61000-4-2 ESD:
.................................................................................4 / 8 KV
EN 61000-4-3 HF radiated:
....................................................................... 10 V/m
EN 61000-4-4 Burst:
.....................................................................................2 KV
EN 61000-4-6 HF conducted:
....................................................................... 10 V
BFSL = Best Fit Straight Line / LS = Limit Value Setting