Fix the sensor to the bypass at the requested height with common cable ties� 

Insert the cable ties through the existing openings of the mounting adapter and 

tighten them firmly�

4.2  Use as proximity sensor
4.2.1  Installation and installation remarks

without mounting adapter

with mounting adapter

1

2

2

1

1: 

sensing face

2: 

plastic plate

S

n

:  nominal sensing range (see data sheet)

A:  distance = S

n

B:  width of the mounting adapter = 36

 

Align the sensing face (1) to the object� 

 

Adhere to the indicated minimum distances to metallic objects opposite and 

beside the sensor (free space)�

 

Non-metallic objects (e�g� plastic fixtures) are allowed within the lateral free 

space�

 

Fix the sensor with appropriate fixing screws to the designated location�

 

If the sensor is installed behind a plastic plate (2), the object will be detected 

through the wall. Depending on the material used and the wall thickness the 

sensor characteristics might change slightly. Do not use conductive plastics! If 

possible, use thin walls�

Summary of Contents for KQ5 Series

Page 1: ...Operating instructions Capacitive sensors KQ5 UK 80222074 00 07 2019 ...

Page 2: ...1 2 Installation on bybass pipes with a mounting adapter 5 4 2 Use as proximity sensor 6 4 2 1 Installation and installation remarks 6 4 2 2 Mounting adapter bore hole dimensions 7 4 2 3 Installation without a mounting adapter 7 4 2 4 Sensor bore hole dimensions 8 5 Electrical connection 8 5 1 Wiring 8 6 Operating and display elements 8 7 Settings 9 7 1 IO Link 9 8 Operation 9 9 Maintenance repair...

Page 3: ...gulations and EC directives Improper or non intended use may lead to malfunctions of the unit or to unwanted effects in your application That is why installation electrical connection set up operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator 3 Functions and features capacitive sensor used as level or proximity sensor detects wit...

Page 4: ...4 3 1 Applications 4 Installation 4 1 Use as a level sensor 4 1 1 Installation on tanks with a mounting adapter 1 2 A 3 B 4 C The mounting adapter is to be ordered separately order no E12153 ...

Page 5: ...in Figure B Fix the sensor with the enclosed screws 3 to the adapter Figure C Fix the mounting adapter including the inserted sensor to the tank at the requested height using suitable screws 7 The sensor can be inserted in the mounting adapter E12153 in both directions Do not place the mounting adapter including inserted sensor in the immediate vicinity of metallic objects 4 1 2 Installation on by...

Page 6: ...B width of the mounting adapter 36 Align the sensing face 1 to the object Adhere to the indicated minimum distances to metallic objects opposite and beside the sensor free space Non metallic objects e g plastic fixtures are allowed within the lateral free space Fix the sensor with appropriate fixing screws to the designated location If the sensor is installed behind a plastic plate 2 the object wi...

Page 7: ...8 4 2 36 3 2 Do not place the mounting adapter including inserted sensor in the immediate vicinity of metallic objects 4 2 3 Installation without a mounting adapter Fix the sensor at the intended location using suitable screws or a suitable glue Align the cutouts as shown ...

Page 8: ...national and international regulations for the installation of electrical equipment must be adhered to Disconnect the installation from power and connect the unit 5 1 Wiring p switching types FPKG or FPOG n switching types FNKG or FNOG BN brown BK black BU blue 6 Operating and display elements 2 1 1 sensing face 2 LED ...

Page 9: ...tic information parameter addresses and the necessary information about the required IO Link hardware and software can be found at www ifm com 8 Operation Check whether the unit operates correctly Bring about a sensor response by taking suitable measures Display by LEDs LED yellow OFF switching output disabled LED yellow ON switching output enabled 9 Maintenance repair disposal The operation of th...

Page 10: ...on and the switch off point Leakage current Current for the internal supply of 2 wire units also flows through the load when the output is blocked Current consumption Current for the internal supply of 3 wire DC units Switch point drift Shifting of the switch point owing to changes of the operating conditions e g temperature pressure air humidity Short circuit protection ifm sensors which are prot...

Page 11: ...11 UK Technical data and further information at www ifm com ...

Reviews: