6
►
Fix the sensor to the bypass at the requested height with common cable ties�
Insert the cable ties through the existing openings of the mounting adapter and
tighten them firmly�
4.2 Use as proximity sensor
4.2.1 Installation and installation remarks
without mounting adapter
with mounting adapter
1
2
2
1
1:
sensing face
2:
plastic plate
S
n
: nominal sensing range (see data sheet)
A: distance = S
n
B: width of the mounting adapter = 36
►
Align the sensing face (1) to the object�
►
Adhere to the indicated minimum distances to metallic objects opposite and
beside the sensor (free space)�
►
Non-metallic objects (e�g� plastic fixtures) are allowed within the lateral free
space�
►
Fix the sensor with appropriate fixing screws to the designated location�
►
If the sensor is installed behind a plastic plate (2), the object will be detected
through the wall. Depending on the material used and the wall thickness the
sensor characteristics might change slightly. Do not use conductive plastics! If
possible, use thin walls�