3  Functions and features

The pressure sensor detects the system pressure and converts it into an analogue 

output signal:

→ Type label (A): I

A

 for PC3xxx or U

A

 for PC9xxx.

3.1  Applications

• 

Type of pressure: relative pressure 

•  Measuring range → Type label (D) / P

Range

•  Permissible overload pressure → Type label (C) / P

max

Avoid static and dynamic overpressure exceeding the given overload 

pressure by taking appropriate measures.

If the overload pressure is exceeded, the unit may be destroyed. NOTE: 

Risk of injury!

4  Installation

Before installing and removing the unit: make sure that no pressure is 

applied to the system.

 

► Insert the unit into a suitable process connection → Type label (E) / Port Size.

 

Tighten firmly. Tightening torque: max. 25 Nm.

5  Electrical connection

The unit must be connected by a qualified electrician.

The national and international regulations for the installation of electrical 

equipment must be adhered to.

Voltage supply to EN 50178, SELV, PELV.

 

► Disconnect power.

 

► Connect the unit as indicated on the unit → Type label (A, B).

Technical data and further information at www.ifm.com