14
7.8 Connect process / dialogue module and cameras
►
Use adapter cables and, if necessary, connection cables�
Connection principle: Connect process / dialogue module CR1201 and two
cameras O2M20x to the MultiViewBox
MultiViewBox
3
4
Display
1
3
2
4
6
8
5
7
2
1
3
4
Display
1
1
Cameras
1
1� M16 connection cable (E2M203)
2�
Adapter cable M12 connector ↔ M16 coupling (E2M200)
3� not used *
)
4� Screen connection *
)
*
)
Core colours of ifm adapter cables: 3 = RD (red); 4 = BK (black); GND = GY (grey)
Find more information about adapter or connection cables at:
→ New search → e.g. O2M200 → Accessories
Cover unused connections with protective covers�