Setting of the sensitivity with stationary objects*
You can also proceed in reverse order: first setting without the object, then with
the object.
* The sensitivity can also be set in exactly the same way using the programming wire (pin
2 / WH). To activate the functions the programming wire is connected for the appropriate
time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units. Feedback: If set-
ting was not successful via the programming wire, the output will switch for 2s. The unit
then reverts to the operating mode with the sensitivity unchanged.
9
Press for about 2s
until the red LED flashes.
Activate the programming mode of the unit.
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
1
Set the sensitivity
with
object.
Press once.
The yellow and green LEDs go out for approx. 1s,
then flash again alternately.
2
Press once.
The yellow and green LEDs go out for approx. 1s,
after approx. 3s the green LED is on.
The unit is in the operating mode.
3
Set the sensitivity
without
object.