4 Electrical connection

The unit must be connected by a qualified electrician.

 

► The national and international regulations for the installation of electri-

cal equipment must be adhered to.

 

► Ensure voltage supply to EN 50178, SELV, PELV.

 

► Disconnect power.

 

► Connect the unit as follows:

DC PNP

DC NPN

L+

L

1

4

3

Cable

BN

BK

BU

L+

L

Core colours:

BN (brown), BU (blue), BK (black).

5 Operation

 

► Check whether the unit operates correctly.
•  Light-on switching units (O7H-HPKG): The output is switched / the yellow LED 

is lit when an object is detected. 

•  Dark-on switching units (O7H-DPKG): the output is switched / the yellow LED 

is lit when no object is detected. 

6 Maintenance, repair and disposal

 

► Keep the front pane of the sensor free from soiling.

 

► For cleaning do not use any solvents or cleaning agents which could damage 

the plastic material.

Technical data and further information at www.ifm.com