18
►
Remove the rod from the unit�
►
Shorten the rod�
►
Remove all burrs and sharp edges�
►
Screw the rod to the unit again and tighten it� Recommended tightening torque:
4 Nm�
►
Precisely measure the probe length L, note the value� It must be entered during
parameter setting of the unit (→ 10.2).
6.3.2 Shortening of the coaxial pipe
The coaxial pipe and the rod must be of the same end length:
►
Remove fastening bracket and
centring piece (A, B)�
►
Shorten the coaxial pipe to the
requested length: L
K
= L + 9 mm�
►
After shortening, at least one hole
(C) for insertion of the fixing bracket
has to be left�
►
Remove all burrs and sharp edges�
►
Insert centring piece (A) at the
lower end of the pipe and attach it
using the fixing bracket (B) at the
lower hole (C)�
A
B
C
L
K
= length of the coaxial pipe
L = length of the rod from the lower edge
of the process connection