6. Programming
Take the following 3 steps for programming:
If no button is pressed for 20 s during the setting procedure, the unit
returns to the operating mode.
Locking / Unlocking
The unit can be electronically locked to prevent unwanted adjustment
of the set parameters: Press (in Run mode) both pushbuttons for 10 s.
As soon as the indication goes out the unit is locked or unlocked.
Units are delivered from the factory in the unlocked state.
With the unit in the locked state
is indicated briefly when you try
to change parameter values.
20
1
Mode/Enter Set
Mode/Enter Set
Mode/Enter Set
Press the
Mode/Enter
button
several times until the
respective
parameter
is displayed.
Press the
Set
button and keep
it pressed. The current
parameter
value
is indicated for 5 s,
then
the value
is increased
*
(incremental by pressing briefly or
scrolling by holding pressed).
Press the
Mode/Enter
button
briefly
(= acknowledgement).
The parameter is displayed again,
the set
parameter value
becomes effective
.
2
3
*Decrease the value: Let the display of the parameter value move to the
maximum setting value. Then the cycle starts again at the minimum setting
value.
Wait 5 s (the unit passes to the
operating mode
and
the current measured value is indicated again),
or start again with
step 1
to program
other parameters
.