1. Function and features
• The pressure sensor
detects the system pressure
,
• shows the current system pressure on its
display
(indication as
from 1% to 105% of the value of the measuring range),
• and generates
2 output signals
according to the set output
configuration.
Applications
Type of pressure: relative pressure
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
For gaseous media the application is limited to max. 25 bar.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
Indication of the current system pressure as from 1% of the
value of the measuring range. Display "0" does not mean that
the system is free of pressure!
15
ENGLISH
output 1
hysteresis function / N.O. (
Hno
)
hysteresis function / N.C. (
Hnc
)
window function / N.O. (
Fno
)
window function / N.C. (
Fnc
)
output 2
analog 4 ... 20 mA
Bursting
pressure
Permissible
overl. pressure
Measuring
range
Order no.
PN3xx0/PE3xx0
0 ... 400 bar
600 bar
1000 bar
PN3xx1/PE3xx1
0 ... 250 bar
400 bar
850 bar
PN3xx2/PE3xx2
0 ... 100 bar
300 bar
650 bar
PN3xx3/PE3xx3
0 ... 25 bar
100 bar
350 bar
PN3xx4/PE3xx4
0 ... 10 bar
50 bar
150 bar
PN3xx6/PE3xx6
0 ... 2,5 bar
20 bar
50 bar
PN3xx7/PE3xx7
0 ... 1 bar
10 bar
30 bar
PN3x29/PE3x29
-1 ... 0 bar
10 bar
30 bar