11
ENGLISH
Menu structure
[bar]
SET S
ENTER R
SET R
ENTER S
[bar]
SET S
ENTER R
SET R
ENTER S
Run
Mode
10
20
30
40
50
60
70
80
90
100
OUT
1 x
> 5s
[bar]
SET S
ENTER R
SET R
ENTER S
[bar]
SET S
ENTER R
SET R
ENTER S
> 5s
1 x
[bar]
SET S
ENTER R
SET R
ENTER S
1 x
[bar]
SET S
ENTER R
SET R
ENTER S
1 x
5s
5s
system pressure / switch-on
point (in 10% steps)
display of switch-on point (S)
(in 1% steps)
display of switch-off point (R)
(in 1% steps)
setting of switch-on point (S)
setting of switch-off point (R)
40
80
120
160
200
240
280
320
360
400
OUT
32bar = 152bar
Display of S / R in 1% steps)
= value of the lit LED (
)
+ 1/10 of the value of the flashing
LED (
)
PBxxx0
0 ... 400 bar
25
50
75
100
125
150
175
200
225
250
OUT
75bar + 20bar = 95bar
PBxxx1
0 ... 250 bar
10
20
30
40
50
60
70
80
90
100
OUT
30bar + 8bar = 38bar
PBxxx2
0 ... 100 bar
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
OUT
0,3bar + 0,08bar = 0,38bar
PBxxx7
0 ... 1 bar
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
OUT
0,75bar + 0,2bar = 0,95bar
PBxxx6
0 ... 2,5 bar
1
2
3
4
5
6
7
8
9
10
OUT
3bar + 0,8bar = 3,8bar
PBxxx4
0 ... 10 bar
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
OUT
7,5bar + 2bar = 9,5bar
PBxxx3
0 ... 25 bar