Manual adjustment to minimum flow (LO-Teach)
The unit detects the current flow and sets this value as the minimum
display value for the LED display. In normal operation the first green
LED (LED 0) flashes when the flow falls below this value (or when it
comes to a standstill).
NOTE:
The LO-Teach operation may only be carried out after the HI-
Teach operation.
ENGLISH
35
2
1
3
Press the
Mode/Enter
button
four times.
LED 0 flashes.
Press the
Learn/Set
button and
keep it pressed.
after 5 s the LED bar (green) fills
from right to left
(release the button as soon as the
first LEDs light),
after this LED 0 is lit.
LO
HI
LO
HI
LO
HI
4 x
M
S
M
S
4
Press the
Mode/Enter
button
briefly (acknowledgement).
The indication goes off briefly.
The unit stores the current flow as
minimum flow and passes into
the operating mode.
HI
LO
M
S
>5 s
Allow the medium to flow through the system at the required
minimum flow rate
or bring to a
standstill
.
M