Setting of switch point (SP) / trigger point (TP)
The switch point is preset at the factory (LED 7).It is always higher than
the trigger point.
Setting range for SP: TP
↔
LED 9,
setting range for TP: LED 0
↔
SP.
32
*Decrease SP / TP: Let the flashing and lit LEDs move to the maximum setting
value. Then the cycle starts again at the minimum setting
value.
**Overflow: If the flashing LED and the lit LED exceed the maximum setting
value, the cycle starts again at the minimum setting value.
1
2
Press the
Mode/Enter
button
once or twice. The setting is
indicated:
LED lit: coarse setting, LED
flashes: fine setting.
Press the
Learn/Set
button and
keep it pressed.
After 5 s the switch point is
increased* (incremental by
pressing briefly or scrolling by
holding pressed).
Indication:
The flashing LED moves from left
to right. After LED 9 has been
reached the cycle starts again at
LED 0. The LED which is constantly
lit moves on by one position.**
LO
HI
LO
HI
LO
HI
M
S
M
S
3
Press the
Mode/Enter
button
briefly (acknowledgement).
The indication goes off briefly.
The setting becomes effective;
the unit passes into the operating
mode.
HI
LO
M
S
>5 s
1 x (SP)
2 x (TP)