Applications
The level sensor LK81 was specially designed to meet the require-
ments of machine tool building. It is specially suitable for monitoring
coolant emulsions (also dirty) as well as cutting and hydraulic oils.
Restriction of the application area
• The sensor is not suitable for extremely conductive and adhering
media, granulates and bulk materials, acids and alkalis. It is not suit-
able for food and electroplating applications.
• The sensor is not suitable for use in grinders.
• It is possible that foam of good conductivity is detected as level.
Check the effects in your application.
• For water and hydrous media with temperatures > 35°C the unit
must be mounted into a climatic tube (order no. E43100, E43101,
E43102).
Measuring principle
The sensor determines the level of fluids according to the capacitive
measuring principle:
• An electrical field is generated and influenced by the medium to be
detected. This change to the field causes a measurement signal that
is electronically evaluated.
• The dielectric constant of a medium is important for its detection.
Media with a high dielectric constant (e.g. water) generate a strong
measurement signal, media with a low dielectric constant (e.g. oils)
a correspondingly lower signal.
• The active measurement zone of the sensor probe is composed of
16 capacitive measuring segments. They generate measurement
signals depending on the degree of coverage.
26
Function and features
Functional overview