15
UK
9.5 Response times
(Without response time of the monitoring unit)
Response time on safety request (removal from the enable zone)
≤
20 ms
1)
Response time when approaching the close range
(non safety-related zone)
≤
T
Response time when approaching the enable zone (enable time)
typ�
≤
100 ms
200 ms
2)
Response time when switching off the clock input
≤
2 ms
Response time for enabling to rising edge of TE
(damped in the enable zone)
typ�
max�
40 ms
100 ms
Response time / risk time for safety-related faults
≤
T
Permissible dwell time in the close range
approx� 2 s
Time delay for activation of the adjustment mode
(→ 8�1 Activate adjustment mode)
approx� 5 s
Dwell time in the undamped condition (
≥
35 mm) to return into the
operating mode (→ 8�3 End adjustment mode)
approx� 2 s
1)
During this time the output is switched off (logic "0")�
2)
As from this instant the clock input signal is transferred to the output with a delay�