![IFM Electronic ECOMAT100 CR2500 Installation Instructions Manual Download Page 9](http://html.mh-extra.com/html/ifm-electronic/ecomat100-cr2500/ecomat100-cr2500_installation-instructions-manual_621125009.webp)
UK
SmartController CR2500
9
► Connect supply and ground cables to the controller and the sensors/actuators
via the respective common star point�
If a prewired connection cable is used, remove the cores with unused signal
inputs and outputs�
Unused cores, in particular core loops, lead to interference coupling that
can influence the connected controller�
5.5 Frequency and analogue inputs
► Operate inputs with screened cables, so that useful signals are not affected by
external interference�
► Connect screens to ground on one side�
6 Set-up
6.1 Programming
The user can easily create the application software by means of the IEC 61131-3
compliant programming system CODESYS 2�3�
6.2 Required documentation
In addition to the CODESYS programming system, the following documents are
required for programming and set-up of the device:
● Programming manual CODESYS V2�3
(alternatively as online help)
● SmartController system manual
(alternatively as online help)
The manuals can be downloaded from the internet:
www.ifm.com → Data sheet search → CR2500 → More information
CODESYS and SmartController online help:
www.ifm.com → Service → Download → Systems for mobile machines*
*) Download area with registration