UK
Device manual CR3105/CR3106
41
Electromagnetic compatibility (EMC), Immunity for industrial environments
(EN 61000-6-2)
Electromagnetic compatibility (EMC), Emission standard for residential, commercial and
light-industrial environments (EN 61000-6-3)
4 kV / 8 kV (EN 61000-4-2)
10 V/m (EN 61000-4-3, ENV 50204)
1 kV / 2 kV (EN 61000-4-4)
0.5 kV (EN 61000-4-5)
10 V (EN 61000-4-6)
30 A/m (EN 61000-4-8)
Class B (CISPR 16-2)
Class B (CISPR 16-2)
Class A (CFR Ch.1)
22...500 Hz: 3 g (EN 60068-2-6, Test Fc)
30 g: 18 ms (EN 60068-2-27, Test Ea)
10 Hz: 20 m
2
/s
3
(EN 60068-2-64, Test Fh)
20...30 Hz: 36 m
2
/s
3
180...2000 Hz: 1 m
2
/s
3
CAN mode (CAN)
Data transmission error (ERROR),
Operating voltage (ON),
Serial interface (RS 232),
GSM mode (GSM)
Control systems
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
17.09.2014
We reserve the right to make technical alterations without prior notice!
CR3105 / page 2
CR3105
CE marking
Electrical tests
Electrostatic discharge immunity
Electromagnetic field immunity
Electrical fast transient/burst immunity
Surge immunity
Conducted disturbance immunity
Magnetic field immunity
Conducted Emissions
Radiated Emissions
FCC Part 15/47
Mechanical tests
Vibration (sinusoidal)
Shock
Vibration (broadband random)
Mounting variants
Display
(status LED)
Wiring
(CAN)
Wiring
(RS 232)
2
4
3
1
5
Description
Pin Potential
Operating voltage
1
GND
2
10...30 [V DC]
CAN interface
3
CAN_GND
4 CAN_H
5 CAN_L
Pin Potential
1 n.c.
2 TxD
3 RxD
4 DSR
5 GND
6 n.c.
7 n.c.
8 n.c.
9 n.c.
variant A
variant B
1
2
3
4
5
6
7
8
9