5. Specification
Main supply
Mains supply 3-phase L
1
/L
2
/L
3
+ N + PE
DC charger input
Mains 3-phase voltage range (phase to phase)
V
AC
400 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
+4%/-6%
Nominal input current
I
IN
83A
Nom
Power Factor
PF
0,98
Nom
Efficiency
ɳ
94 %
Max
Harmonic current @ nominal network voltage
THDi
< 16 % (@ P
out
> 0,3 P
max
) Max
AC charger input
Mains 3-phase voltage range (phase to phase)
V
AC
400 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
+4%/-6%
Nominal input current
I
AC
32A
Nom
Technical specification
DC charger internal AC input protection
Inrush current limitation per phase
I
INRUSH LIMIT
< 3 x I
AC
Max
Max earth leakage current
I
LEAKAGE
< 3,5 mA
Max
Emergency button connection
Yes
Overvoltage category
III
DC Output
Output voltage
V
DC
_max
500 V
DC
Max
V
DC
_min
200 V
DC
Min
Output current
I
DC
_max
125A
(1)(2)
Max
I
DC
_min
1,5A
Min
Max Output Power
P
OUT
50kW
Max
Output connector (charging station side)
Permanent mounting
Car Plug connectors
COMBO 2
CHAdeMO
Output cable length
Meters
4m
DC output protection
Hardware and software short circuit protection
Yes
Hardware over voltage protection
+20% max
Software over voltage protection
dynamic
+10% max
Over temperature protection
-
70°C
Reverse polarity protection
Yes
DC output Contactor
Yes (2 poles)
Rated Current Fuse (output)
I
FUSE
200
A
Galvanic isolation
V
input / output
4100
V
DC