background image

www.ies-synergy.com

User Manual 

DUM017749-EN

2

The information provided in this documentation contains general descriptions and/or technical characteristics 

of the performance of the products contained herein. This documentation is not intended as a substitute for 

and is not to be used for determining suitability or reliability of these products for specific user applications. It 

is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and 

testing of the products with respect to the relevant specific application or use thereof. Neither IES Synergy nor 

any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 

If you have any suggestions for improvements or amendments or have found errors in this publication, please 

notify us.

You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this document 

on any medium whatsoever without permission of IES Synergy, given in writing. You also agree not to establish 

any hypertext links to this document or its content. IES Synergy does not grant any right or license for the per-

sonal and noncommercial use of the document or its content, except for a non-exclusive license to consult it on 

an “as is” basis, at your own risk. All other rights are reserved.

All pertinent state, regional, and local safety regulations must be observed when installing and using this prod-

uct. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer 

should perform repairs to components.

When devices are used for applications with technical safety requirements, the relevant instructions must be 

followed.

Failure to use IES Synergy software or approved software with our hardware products may result in injury, 

harm, or improper operating results.

Failure to observe this information can result in injury or equipment damage.

© 2020 IES Synergy. All rights reserved.

Summary of Contents for Keywatt 50 Series

Page 1: ...User Manual Keywatt 50 Station Bus www ies synergy com DUM017749 EN_V001b...

Page 2: ...our own personal noncommercial use all or part of this document on any medium whatsoever without permission of IES Synergy given in writing You also agree not to establish any hypertext links to this...

Page 3: ...eral Safety instructions 6 4 Overview 7 External view 7 5 Specification 8 Main supply 8 3 phase L1 L2 L3 N GND 3x400VAC 8 Technical specification 8 Compliance 10 Derating 10 6 Utilization 12 Human Mac...

Page 4: ...tions are not followed This is the safety alert symbol It is used to alert you to potential personnal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death...

Page 5: ...aims to provide informations needed for the use of the Keywatt 50 Station Bus This guide must be read with other related documents This guide is intended for users of the charging stations Document s...

Page 6: ...racked opened or show any other indication of damage Replace the damaged cables by same caracteristics cables Do not use a cord extension set second cable assembly or adaptors in addition to the cable...

Page 7: ...GOING CHARGE ENDED WARNING ERROR START STOP Position Description Lifting rings Touch screen Connector holster in option State of charge Door lock RJ45 input for maintenance only Power button START STO...

Page 8: ...sh current limitation per phase IINRUSH LIMIT 3 x IAC Max Rated current circuit breaker IBREAK Rating 100A typ Rated short circuit capacity IBREAK Capacity 15 kA Max Max earth leakage current ILEAKAGE...

Page 9: ...ic level 1m all directions Db A 58 9 dbA 1m Climatic Environment constraints Operating temperature with derating 25 C to 50 C 3 Storage temperature 25 C to 70 C Relative humidity RH 5 to 95 Installati...

Page 10: ...vehicle for control of DC charging in the Combined Charging System DIN 70121 Vibration and shock resistance STD ASTM D 4169 16 STD ASTM D 880 92 STD ASTM D 4728 17 STD ASTM D 6055 96 STD ASTM D 6179 0...

Page 11: ...www ies synergy com User Manual DUM017749 EN 11...

Page 12: ...achine interface HMI Lights Charger ready CCS connected Charging Charge ended Warning Error Start a charge session Before starting a charge session ensure the unit is properly assembled in accordance...

Page 13: ...with the electrical vehicle to collect information All these steps are necessary to adapt the charging station parameters to the EV EV charge While the EV is charging the charging station shows the in...

Page 14: ...Emergency Stop In the event of an emergency the Emergency Stop button may be pressed to instantly stop charging To emergency stop follow these steps 1 Press the emergency stop button bellow the charg...

Page 15: ...our vehicle when plugging until the charge has started Please un plug your vehicle Error occurred 0x3A Your battery model is incompatible with this char ger Please unplug your vehicle Your battery mod...

Page 16: ...the following messages are displayed on the charging station s screen the charge is unavailable Message Description Charger inoperative Cannot charge here Charger inoperative Backend server request ch...

Page 17: ...intenance work to ensure that it is separated from the supply of AC mains Failure to do so may cause physical injury or damage to the electrical system and charging unit Maintenance of the charging st...

Page 18: ...www ies synergy com User Manual DUM017749 EN 18 Notes...

Page 19: ...www ies synergy com User Manual DUM017749 EN 19 Notes...

Page 20: ...ine Bergfeldstr 11 34130 Saint Aun s 83607 Holzkirchen France Germany Tel 33 0 4 99 13 62 80 Tel 49 0 80244633980 Fax 33 0 4 99 13 62 81 IES Synergy Inc USA IES WANMA New Energy China 330 East Maple R...