User manual
DUM1017795-EN
13
Embedded Insulation device
Fault trigger threshold (CCS, CHAdeMO and
GB before charging only)
100 Ω/V
± 10%
Warning detection threshold (CCS only)
500 Ω/V
± 10%
Line voltage L+/L- (Un)
DC 200V…500V
System leakage capacitance Ce
≤ 1μF: response value (Ran) and time (tan) are not guar
-
anteed for capacitance over 1μF.
General & dimensions
External dimensions (mm)
H x L x D
927 x 730 x 702 mm
Weight (without cable)
kg
150kg
Max
Type of installation
Trolley (4 wheels)
Protection type (EN60529)
IP
IP21
Cooling systems
Heatsink with forced air flow by fans IP54
without air filter
Climatic & Environment constraints
Operating temperature (with derating)
-20°C to +40°C
(3)
Storage temperature
-40°C to +70°C
Relative humidity (without condensation)
RH
10% to 95%
Installation altitude
Alt
2 000m
Max
Pollution category
2
(1)
Max output current will be adapted versus maximum carrying current of the vehicle plug.
(2)
Output current can be even reduced with the power derating versus temperature.
(3)
Potential derating above 30°C.
(4)
Refer to the current derating curve according to the mains voltage.