WAFER-AL SBC
Page 62
4.7.6 RS-232/422/485 Mode Select Switch
Jumper Label:
SW2
Jumper Type:
DIP switch
Jumper Settings:
See
Jumper Location:
See
The SW2 selects RS-232/422/485 mode of the COM1 and COM2 serial ports.
SW2 (1)
SW2 (2)
Description
ON
ON
COM1 RS-422
ON
OFF
COM1 RS-232 (Default)
OFF
ON
COM1 RS-485
SW2 (3)
SW2 (4)
Description
ON
ON
COM2 RS-422
ON
OFF
COM2 RS-232 (Default)
OFF
ON
COM2 RS-485
Table 4-5: RS-232/422/485 Mode Selection