![IEI Technology TANK-720 User Manual Download Page 69](http://html.mh-extra.com/html/iei-technology/tank-720/tank-720_user-manual_619484069.webp)
TANK -720 E mbedded S ys tem
P age 56
Intel Virtualization Technology [Dis abled]
Use the
Intel Virtualization Technology
option to enable or disable virtualization on the
system. When combined with third party software, Intel Virtualization technology allows
several OSs to run on the same system at the same time.
Disabled
D
EFAULT
Disables Intel Virtualization
Technology.
Enabled
Enables Intel Virtualization Technology.
4.3.3.1
C P U Information
Use the
CPU Information
submenu (
) to view detailed CPU specifications
and configure the CPU.
Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
Advanced
CPU Configuration
Intel(R) Core (TM) i3-2100T CPU @ 2.50GHz
CPU Signature
206a7
Microcode Patch
14
Max CPU Speed
2500 MHz
Min CPU Speed
1600 MHz
Processor Cores
2
Intel HT Technology
Supported
Intel VT-x Technology
Supported
Intel SMX Technology
Not Supported
L1 Data Cache
32 kB x 2
L1 Code Cache
32 kB x 2
L2 Cache
256 kB x 2
L3 Cache
3072 kB
----------------------
: Select Screen
↑
↓
: Select Item
Enter Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Version 2.11.1210. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 6: CPU Configuration
The CPU Configuration menu (
) lists the following CPU details:
Processor Type: Lists the brand name of the CPU being used
CPU Signature: Lists the CPU signature value.
Microcode Patch: Lists the microcode patch being used.
Max CPU Speed: Lists the maximum CPU processing speed.
Summary of Contents for TANK-720
Page 9: ...TANK 720 E mbedded S ys tem Page ix E HAZARDOUS MATERIALS DISCLOSURE 103 ...
Page 14: ...TANK 720 E mbedded S ys tem Page 1 Chapter 1 1 Introduction ...
Page 23: ...TANK 720 E mbedded S ys tem Page 10 Chapter 2 2 Unpacking ...
Page 28: ...TANK 720 E mbedded S ys tem Page 15 Chapter 3 3 Ins tallation ...
Page 39: ...TANK 720 E mbedded S ys tem Page 26 Figure 3 13 AT ATX Power Mode Switch ...
Page 61: ...TANK 720 E mbedded S ys tem Page 48 Chapter 4 4 B IOS ...
Page 99: ...TANK 720 E mbedded S ys tem Page 86 Appendix A A R egulatory Compliance ...
Page 105: ...TANK 720 E mbedded S ys tem Page 92 Appendix B B B IOS Options ...
Page 108: ...TANK 720 E mbedded S ys tem Page 95 Appendix C C S afety Precautions ...
Page 113: ...TANK 720 E mbedded S ys tem Page 100 Appendix D D Digital I O Interface ...
Page 116: ...TANK 720 E mbedded S ys tem Page 103 Appendix E E Hazardous Materials Dis clos ure ...