NOTE:
System power can switch between Power 2 and Power 1 automatically
when
a 12 V power adapter is being connected to Power 2 and the
power input of Power 1 is from 9 V to 16 V. If Power 2 is unplugged and
the power input of Power 1 is over 16 V, system power will switch to
Power 1 automatically. However, the system remains using the power
source from Power 1 even if Power 2 is re-plugged.
System power can switch between Power 2 and Power 1 automatically
when
a 19 V power adapter is being connected to Power 2 and the
power input of Power 1 is from 9 V to 26 V. If Power 2 is unplugged and
the power input of Power 1 is over 26 V, system power will switch to
Power 1 automatically. However, the system remains using the power
source from Power 1 even if Power 2 is re-plugged.
3.9.2.3
S h u td o wn
The system will shutdown in the following situations:
Power 2 < 10.5V and Power 1 < 9V
Press Power buttons for 6 seconds
The following flow diagram shows the system shutdown process and the LED statuses.
Figure 3-37: ACC Off: Shutdown