IEI Technology RACK-360 Quick Installation Manual Download Page 5

 

RACK-360 QIG                         IEI Integration Corp.                                   Page 5 

 

 

 

Figure 8: Remove the Slot Cover Retention Screw 

Step 2: 

Slide the CPU card into the socket on the backplane 

reserved for the CPU card. (Se

Figure 9

) 

 

 

Figure 9: Slide the CPU Card into the Sockets 

Step 3: 

To secure the CPU card, reinsert the previously removed 

slot cover retention screw.

Step 0:

 

STEP 7: PCI/ISA EXPANSION CARD 

INSTALLATION 

The RACK-360G/RACK-360E supports up to 14 PCI/ISA expansion 

cards and the RACK-360GxATX/RACK-360ExATX variant supports 

up to seven PCI/ISA expansion cards. To install an expansion card 

(PCI or ISA) please follow the steps below. 

Step 1: 

Remove the slot cover at the back of the chassis. To do 

this, remove the slot cover retention screw at the top of 

the slot cover. 

Step 2: 

Slide the PCI/ISA expansion card into reserved PCI/ISA 

socket on the backplane. 

Step 3: 

To secure the PCI/ISA expansion card,  reinsert the 

previously removed slot cover retention screw.

Step 0:

 

STEP 8: DISK DRIVES INSTALLATION 

The RACK-360  chassis  has  two drive brackets: one main drive 

bracket and a side bracket. The main drive bracket supports up to 

three 5.25" optical drives or two 5.25" drives and one 3.5" drive (HDD 

or FDD). The side bracket only supports one 3.5" FDD drive   

 

To install the drives, please follow the steps outlined in the sections 

below. 

S

TEP 

8.1:

 

R

EMOVE THE 

S

IDE 

B

RACKET

 

Before any drives can be installed, the side bracket attached to the 

main drive bracket must be removed. To remove the side bracket, 

remove the two retention screws from the top of the side bracket that 

secure the side bracket to the main bracket. 

 

 

Figure 10 

Remove the Side Bracket 

S

TEP 

8.2:

 

I

NSTALL 

3.5"

 

D

RIVES INTO THE 

S

IDE 

B

RACKET

 

The side bracket supports one 3.5" FDD. If you want to install a 3.5" 

FDD drive into the side bracket, please follow the steps below. 

Step 1: 

Remove the front flap from the side bracket by removing 

the two retention screws that secure the front flap to the 

side bracket.   

Step 2: 

Place a 3.5" FDD drive into the bracket. Make sure the 

FDD is upright and both the IDE/SATA drive interface 

connector and the 4-pin power connector are facing the 

rear of the bracket.

 

Step 3: 

To secure the 3.5" FDD to the side bracket, insert four 

retention screws. 

Step 0:

 

S

TEP 

8.3:

 

R

EMOVE THE 

M

AIN 

D

RIVE 

B

RACKET 

 

If you wish to install 5.25" optical drives or more than one 3.5" drives 

(HDD or FDD), the main drive bracket must be removed. To remove 

the main drive bracket from the chassis, follow the steps below. 

Step 1: 

Remove the side bracket. See 

S

TEP 

8.1:

 

R

EMOVE THE 

S

IDE 

B

RACKET

 above. 

Step 2: 

Remove the four retention screws that attach the main 

bracket to the base of the chassis.

  Step 0:

 

Summary of Contents for RACK-360

Page 1: ...ombinations o 3 x 5 25 Optical drives o 2 x 5 25 Optical drives 1 x 3 5 HDD hard disk drive 1 x 3 5 FDD floppy disk drive o 2 x 5 25 Optical drives 2 x 3 5 FDDs Dimensions DxWxH o 435 5mm x 431mm x 17...

Page 2: ...60 QIG IEI Integration Corp Page 2 DIMENSION DRAWING The dimensions of RACK 360 are shown on the diagram below 431 00 320 00 176 00 176 00 431 00 I O Figure 1 Dimension Drawing measurement units milli...

Page 3: ...ALLATION Two handles are shipped with the RACK 360 chassis The handles are installed on the sides at the front of the chassis Each handle is secured to the chassis by four retention screws To install...

Page 4: ...Screws STEP 5 BACKPLANE INSTALLATION The IEI backplanes listed below are compatible with the RACK 360 chassis Model No SBC Type PCI ISA PSU Type PCI 13SD RS PCIMG 1 0 3 4 3 3 AT ATX PCI 14S2 RS PCIMG...

Page 5: ...FDD drive To install the drives please follow the steps outlined in the sections below STEP 8 1 REMOVE THE SIDE BRACKET Before any drives can be installed the side bracket attached to the main drive b...

Page 6: ...four retention screws that secure the 3 5 drive tray to the main drive bracket and then slide the 3 5 drive tray out of the main drive bracket Figure 12 Remove the Front Metal Cover Retention Screws...

Page 7: ...through the sides of the drive bracket and into the HDD Step 6 Reinsert the 3 5 drive tray with the installed 3 5 FDD into the main drive bracket Make sure that the 4 pin FDD power connector and the I...

Page 8: ...REPLACEMENT NOTE Please ensure that the power of the computer is switched off before you replace a fan There is one 12 cm cooling fan inside the RACK 360 chassis To replace a fan please follow the ste...

Page 9: ...the tab and pull the fan filter out to the right See Figure 20 Figure 20 Remove the Fan Filter Step 2 Replace the filter pad inside Step 3 Slide the fan filter back into the chassis Step 0 NOTE To pur...