![IEI Technology IOPS-Q67/H61 User Manual Download Page 70](http://html1.mh-extra.com/html/iei-technology/iops-q67-h61/iops-q67-h61_user-manual_3879671070.webp)
IOPS-Q67/H61 Pluggable Module PC
Page 60
NOTE:
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
Example program:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
MOV AX, 6F02H
;setting the time-out value
MOV BL, 30
;time-out value is 48 seconds
INT 15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1
;is the application over?
JNE W_LOOP
;No, restart the application
MOV AX, 6F02H
;disable Watchdog Timer
MOV BL, 0
;
INT 15H
;
; EXIT ;