The Host System (SMBus Host) requests information from the battery and then uses it to
provide the user information about the battery present state and capabilities. The Host
System (SMBus Host) also receives critical events from the Smart Battery when it detects
a problem. Using the utility software, the battery state and capabilities can be shown in the
Host System through RS-232.
2.2 Safety
Both the battery and the IDDUPS series must agree it is safe enough to begin charging. If
the battery detects some error conditions, the charging never begins. The error conditions
might include:
battery pack voltage too high or low,
temperature out of acceptable ranges,
individual cell voltage shorted.
Furthermore, to continue charging, both the battery and the IDDUPS series must be
satisfied it is still safe to do so. The battery sends a message or stop sending messages to
the IDDUPS series to terminate charge if any error condition occurs in the battery. Second,
the IDDUPS series monitors the battery pack Safety Signal terminal. If the Safety Signal
moves out of a range that allows charging, the IDDUPS series immediately terminates
charge. This could happen if the temperature of the battery pack got too hot.
These mechanisms are independent of and in addition to any protection mechanisms in
the battery pack itself, for example, fuses or protection FETs controlled by hard-wired
safety circuitry.
2.3 Battery Specifications
The IDDUPS series may also come with a Li-Polymer smart battery. Some of the
Li-Polymer smart battery specifications are listed in
192H192H192H195H
Table 2-1
.
Battery Type
Li-Polymer
Nominal Capacity
3000mAH
Nominal Voltage
7.4V (Two 3.7V Li-Polymer battery cell)
Summary of Contents for IDDUPS-6364120A/636260A
Page 9: ...IDDUPS Series DC DC Converter Module Page 9 1 Introduction Chapter 1 ...
Page 12: ...IDDUPS Series DC DC Converter Module Page 12 2 Detailed Specifications Chapter 2 ...
Page 16: ...IDDUPS Series DC DC Converter Module Page 16 3 Unpacking Chapter 3 ...
Page 21: ...IDDUPS Series DC DC Converter Module Page 21 4 Connector Pinouts Chapter 4 ...
Page 35: ...IDDUPS Series DC DC Converter Module Page 35 5 Software Application Chapter 5 ...
Page 43: ...IDDUPS Series DC DC Converter Module Page 43 Appendix A A Safety Precautions ...
Page 49: ...IDDUPS Series DC DC Converter Module Page 49 Appendix B B Hazardous Materials Disclosure ...