5.7
Wiring
5.7.1
Initiators
Inductive proximity switches (NC normally closed contacts, article no.: 25165) are available
optionally for the running path (see Figure 22, page 29).
These switches are no safety limit switches according to DIN EN 60204-1:2014-10 (Safety of
machinery - electrical equipment of machinery - part 1: general requirements).
Optionally, an additional reference point switch (PNP normally open contacts, article no.: 726744,
see Figure 23,
29), can be installed in module 60/33 (also subsequently).
The active button is marked with a coloured circle. Normally closed contacts are marked with a
green, normally open contact with a red dot.
The initiators and their supply lines are protected in an integrated cable channel and are wired to a
joint plug.
The initiator can be replaced by moving the strip in the lifting direction.
The switching position can be set at any time by moving the slot nuts.
View of plug at module 60/33
Plug housing and plug for initiators
Slot nut