3.2
Power Up Instructions Sequence
Upon power up, the Daystar Nova module is set to a default mode of operation. Under some power up
circumstances, the default mode may be improperly set. Consequently, the following instructions should
always be executed in the host systems initialization routine.
Step
Operation
1
Function Set for 8 bits
2
Repeat, Function Set for 8 bits
3
Function Set
4
Clear Display
5
Entry Mode Set
6
Display On/Off Control
STEP
RS
R/W
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
1
0
0
0
0
1
1
*
*
*
*
2
0
0
0
0
1
1
*
*
*
*
3
0
0
0
0
1
DL
1
0
*
*
4
0
0
0
0
0
0
0
0
0
1
5
0
0
0
0
0
0
0
1
I/D
S
6
0
0
0
0
0
0
1
D
C
B
Refer to instruction set for values of DL, I/D, S, D, C and B. (* Don't care)
3.3
Instructions Affecting the Relationship of Display Position, Cursor, and DD RAM Address
The DD RAM contains the 8 bit character codes of the 40 characters displayed on the Daystar Nova LCD. The
Cursor or Display Shift instruction and the Write to DD RAM and Entry Mode instructions affect the relationship
between DD RAM address and display position. Figures 6 to 10 illustrate the effects of these instructions.
00*
01
02
03
04
05
06
07
08
09
0A
22
23
24
25
26
27
MPU1
40
41
42
43
44
45
46
47
48
49
4A
62
63
64
65
66
67
00*
01
02
03
04
05
06
07
08
09
0A
22
23
24
25
26
27
MPU2
40
41
42
43
44
45
46
47
48
49
4A
62
63
64
65
66
67
* = Cursor
Figure 6
Initial Conditions on Power Up
01
02
03
04
05
06
07
08
09
0A
0B
23
24
25
26
27
00*
MPU1
41
42
43
44
45
46
47
48
49
4A
4B
63
64
65
66
67
40
00*
01
02
03
04
05
06
07
08
09
0A
22
23
24
25
26
27
MPU2
40
41
42
43
44
45
46
47
48
49
4A
62
63
64
65
66
67
* = Cursor
Figure 7
Display Shift Left from Initial Conditions
27
00*
01
02
03
04
05
06
07
08
09
21
22
23
24
25
26