background image

PAGE 

3

 

DOC: 374B 

REV: 12-12

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION 

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

1. 

Read these instructions.

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water.

6. 

Clean only with dry cloth.

7. 

Install in accordance with the manufacturer’s in-
structions.

8. 

Do not install near any heat sources such as ra-
diators, heat registers, stoves, or other apparatus 
(including amplifiers) that produce heat.

9. 

Only use attachments/accessories specified by the 
manufacturer.

10. 

Refer all servicing to qualified service personnel.  
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord 
or plug is damaged, liquid has been spilled or ob-
jects have fallen into the apparatus, the apparatus 
has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

SAFETY SYMBOLS

Labeling on products and the 

Installation Instructions & 

User Manual

 may use safety related graphical symbols 

as shown below to note safety requirements.

Lightning Bolt:

  The lightning flash with 

arrowhead symbol, within an equilateral triangle, 
WARNING symbol, is intended to alert the user to 
the presence of un-insulated 

dangerous voltage

 

within the product’s enclosure that may be 
sufficient in magnitude to constitute a risk of 
electric shock to persons or domestic animals.

Exclamation Point:

 The exclamation point 

within an equilateral triangle, CAUTION symbol, 
is in-tended to alert the user to the presence of 
important operating and maintenance (servicing) 
instructions, or a hazard that can damage equip-
ment.

Do not proceed beyond a WARNING or CAUTION notice 
until you have understood the hazardous condition and 
have taken appropriate steps.

SPECIFICATIONS

Electrical

Frequency Response  .................................................................................... ±0.5 dB

22 Hz - 22 kHz, Input Level = 0 dBu

Total Harmonic Distortion, THD  ....................................................................... <0.5%

22 Hz - 22 kHz, Input Level = 0 dBu

Signal-to-Noise Ratio, S/N  .............................................................................. >85 dB

22 Hz - 22 kHz, Input Level = 0 dBu

Compressor

Compression Threshold ............................................................................–15 dBu
Ratio ...................................................................................................................5:1
Attack Time ...............................................................................................22 mSec
Release Time ..................................................................................................1 Sec

Maximum Output (Line Output) ...................................................................... +5 dBu
Analog-to-Digital Converter, A/D ......................................................................... 24 bit
Internal Processing  .................................................................... 32 bit, Floating Point
Sample Rate  .....................................................................................................48 kHz
Latency (Through a maximum of 6 network switch hops)  ......................... 5.7 mSec

Mechanical

Desktop Size ......................................................................5.13” W x 5.32” H x 5.66”D

(Desktop mounting requires optional IEDA520DTB)

Wall Mount Size ..................................................................4.95” W x 4.95” H x 1.9” D
Wall Mount mounting ................................................................. 2-gang electrical box

1-gang electrical box (using adapter backbox)

Standards Utilized

Full-Duplex Operations  ...........................................................................  IEEE 802.3x
Fast Ethernet, 100Mbps  .......................................................................... IEEE 802.3u

The 524 Series specifically uses 100Base-TX

Data Terminal Equipment Power  ...........................................................  IEEE 802.3af

via Media Dependent Interface (PoE)

Connecting Cable

Digital Audio/Power/Control  .............................................................  CAT5e or better

For distances to a maximum of 100 Meters (approximately 300 feet) to the con-
nected switch. Cable installed and tested in accordance with ANSI/TIA/EIA 568B 
Standards.

Environmental

Operating Temperature Range  ............................

+32˚F to +104˚F (0˚C to +40˚C)

Storage Temperature Range  .............................–40

˚

F to +158

˚

F (–40

˚

C to +70

˚

C)

Power
Consumption

Supply Power .......................................................................................................<2W

Supply Voltage = 48VDC

NOTE: 

This unit is 

not

 compatible with 500, 510, or 520 series Announcement Control Systems (ACS).

Summary of Contents for IED0520DTB

Page 1: ...INSTALLATION INSTRUCTIONS IEDA524 H IEDA520DTB DIGITAL MICROPHONE STATION REV 12 12 DOC 369B IEDA524 H IED0520DTB DIGITAL MICROPHONE STATION Installation Instructions ...

Page 2: ...ully compatible with IEEE 802 3af standard for Power over Ethernet PoE allowing the 524 to be powered directly from any standard off the shelf PoE switch The processing power for the 524 comes from the onboard 32 bit processor This powerful processor manages the input buttons Ethernet interface audio signal processing and self test diagnostics This and all IED LAN based GLOBALCOM components are de...

Page 3: ...ration software to function as one touch action buttons to trigger any of the following types of announcements or messages A live page to a designated zone group A recorded page to a designated zone group A permanent message playback to a designated zone group e g customer reminder or emergency message Any action type available in the GLOBALCOM configuration software Network Requirements The 524 d...

Page 4: ... alert the user to the presence of important operating and maintenance servicing instructions or a hazard that can damage equip ment Do not proceed beyond a WARNING or CAUTION notice until you have understood the hazardous condition and have taken appropriate steps SPECIFICATIONS Electrical Frequency Response 0 5 dB 22 Hz 22 kHz Input Level 0 dBu Total Harmonic Distortion THD 0 5 22 Hz 22 kHz Inpu...

Page 5: ...ttons These four buttons are used to activate announcements or messages on the announcement controller Their exact function is configured in the announcement controller software 5 Microphone Attachment Location This marks the location for the magnetic receiver where the 501HH handheld microphone is to be placed when not in use The actual magnet is located on the back of the 501HH handheld micropho...

Page 6: ...er 11 Group and Line Level Output Enable DIP Switches DIP switches 1 through 5 are used to set the group number for this microphone station This group number must match the system number of the announcement controller that will own this microphone station DIP switches 6 and 7 are not used DIP switch 8 will enable the line level audio output when turned to the ON position Refer to Group DIP Switch ...

Page 7: ...Installation IEDA520DTB Desktop Base The IEDA520DTB is available as an option when a desktop mounting solution is preferred The IEDA524 H ships with the plastic back box that you can then use to attach the unit to the base as shown in Figure 4 The unit is then secured to the base by tightening the retaining screws using the nuts located on the back of the base mounting plate The microphone station...

Page 8: ... a console Figure 5 illustrates the process for mounting the unit in such an application The washers shown are optional and can be used to prevent the unit from being forced off of the box due to the keyhole mounting points Figure 5 Alternate Single Gang Electrical Box Method A Figure 6 illustrates an alternative mounting option where the box has been rotated 180 to provide a slight backward slant...

Page 9: ... balanced audio cable to the line level audio output connector using the supplied connector as shown in Figure 7 Ensure that DIP switch 8 is set to the ON position Connect the other end of the cable to an appropriate audio device This line level output will become active if the microphone station loses communications with the announcement controller S Set to ON Figure 7 Line Level Audio Output Not...

Page 10: ...vailable group and mic number S Group Address Mic Number Not Used Line Out Enable Figure 8 524 DIP Switch Locations Group DIP Switch Settings Switch 1 2 3 4 5 Group 1 ON OFF OFF OFF OFF 2 OFF ON OFF OFF OFF 3 ON ON OFF OFF OFF 4 OFF OFF ON OFF OFF 5 ON OFF ON OFF OFF 6 OFF ON ON OFF OFF 7 ON ON ON OFF OFF 8 OFF OFF OFF ON OFF 9 ON OFF OFF ON OFF 10 OFF ON OFF ON OFF 11 ON ON OFF ON OFF 12 OFF OFF ...

Page 11: ...F ON ON OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 28 OFF OFF ON ON ON OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON ON OFF OFF ON OFF ...

Page 12: ...N OFF ON OFF 92 OFF OFF ON ON ON OFF ON OFF 93 ON OFF ON ON ON OFF ON OFF 94 OFF ON ON ON ON OFF ON OFF 95 ON ON ON ON ON OFF ON OFF 96 OFF OFF OFF OFF OFF ON ON OFF 97 ON OFF OFF OFF OFF ON ON OFF 98 OFF ON OFF OFF OFF ON ON OFF 99 ON ON OFF OFF OFF ON ON OFF 100 OFF OFF ON OFF OFF ON ON OFF 101 ON OFF ON OFF OFF ON ON OFF 102 OFF ON ON OFF OFF ON ON OFF 103 ON ON ON OFF OFF ON ON OFF 104 OFF OFF...

Page 13: ...ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON 159 ON ON ON ON ON OFF OFF ON 160 OFF OFF OFF OFF OFF ON OFF ON 161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OFF ON OFF ON 164 OFF OFF ON OFF OFF ON OFF ON 165 ON OFF ON OFF OFF ON OFF ON 166 OFF ON ON OFF OFF ON OFF ON 167 ON ON ON OFF OFF ON OFF ON 168 OFF OFF OFF ON OFF ON OFF ON 169 ON OFF OFF ON OFF ON O...

Page 14: ... OFF ON ON ON ON OFF ON ON 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ON ON ON OFF OFF ON ON ON 232 OFF OFF OFF ON OFF ON ON ON 233 ON OFF OFF ON OFF ON ON ON 234 OFF ON OFF ON OFF ON ON O...

Page 15: ...4 H IEDA520DTB DIGITAL MICROPHONE STATION Line Level Audio Output Enable Switch 8 Line Output Enabled ON Line Output Disabled OFF DIMENSIONS 4 952 4 952 1 812 3 281 1 907 900 750 Figure 9 IEDA524 H 5 128 5 318 5 662 Figure 10 IEDA524 H with optional IEDA520DTB ...

Page 16: ... Electronic Designs LLC Innovative Electronic Designs LLC 1 502 267 7436 phone 9701 Taylorsville Road 1 502 267 9070 fax Louisville KY 40299 USA www iedaudio com INSTALLATION INSTRUCTIONS IEDA524 H IEDA520DTB DIGITAL MICROPHONE STATION ...

Reviews: