B5U033000E
Page 31 of 54
Value Definition:
Sub-index 00h contains the number of valid object entries within the record. The
number of valid objects entries shall be the number of the general configuration
parameters. Its value is 03h.
Sub-index 01h to 03h contains a configuration parameter. An attempt to change
the value of the configuration parameter to any not supported value shall be
responded with the SDO abort transfer service (abort code: 06090030h). See
the
BLUEBOX
user manual for value definition details.
Parameter
Description
Range
Default
Mode
How the reader manages the power in
‘continuous’ mode.
Note that this parameter become effective
only after a reboot of the reader.
Off
Up
Up/down
Off
Power Step
The power step in dynamic power management
mode activated.
Note that this parameter become effective
only after a reboot of the reader.
1 … 5 dB
10 … 500 mW
1 dB
Time Step
The time step in dynamic power management
mode activated.
Note that this parameter become effective
only after a reboot of the reader.
0.1 … 9.9
seconds
1.0 sec
Sub-Index
Parameter
Description
01h
Mode
How the reader manages the power in ‘continuous’ mode:
•
0x00: Off;
•
0x01: Up, only increase power by power step every time
step;
•
0x02: Up / Down, increase power and then decrease it by
power step every time step.
02h
Power Step
The power step in dynamic power management mode activated:
•
0x01 … 0x05 for power step in dB (1 … 5 dB);
•
0x81 … 0xB2 for power step in mW x 10 (10 … 500 mW).
03h
Time Step
The time step in dynamic power management mode activated:
•
Decimal 1 … 99 for time in ms x 100 (0.1 … 9.9 seconds).
Object Descritpion:
Index
2203h
Name
Dynamic power configuration