8-1. Connecting a power supply
- C12V of power supply to Red wire.
- Connect GND of power supply to Black wire.
8-2. Connecting a door lock
- Connect (+) wire of door lock to +12V wire of power supply.
- Connect (-) wire of door lock to white wire of reader module.
8-3. Connecting an exit button
- Connect Green wire of exit button input to one wire between wires of exit button.
- Connect GND wire of power supply to the other wire.
8-4. Connecting a door sensor
- Connect COM terminal of door sensor to Blue wire of door sensor input.
- Connect NO terminal of door sensor to GND of power supply.
8-5. Connecting a door lock type
- In a power fail safe, connect GND wire of power supply to Yellow wire of door lock type input.
- In a power fail secure, put a floating state on Yellow wire of door lock type input.
9. Operation
9-1. When power is supplied
(1) All LEDs display red or green. Then they repeat on/off twice and become off.
(2) As power off, red LED turns on from the under to the top in order. And all LEDs turn red.
(3) RFL200 / IP-RFL200’s buzzer sounds one time
9-2. Whether registered key tag is read on RFL200 / IP-RFL200 or an exit button is pressed
(1) All LEDs turn from red to green. From the top to the under, they are off and on in order.
When all LEDs are off, they turn red.
(2) At this time, the door is opened by definite time.
And the upper of two LEDs turn green. This means that open the door
(3) RFL200 / IP-RFL200’s buzzer sounds one time.
9-3. When unregistered key tag is read on RFL200 / IP-RFL200
(1) All LEDs turn red. Then they repeat on/off twice and become on.
(2) RFL200 / IP-RFL200’s buzzer sounds twice.
9-4. If key tag is approached by RFL200 / IP-RFL200 when the door is opened.