iCON100/iCON100-SR QUICK INSTALLATION GUIDE
15
Alarm Device Connection (Relay #2)
- Connect COM port of Relay #2 to DC+12V
- Connect NO port of Relay #2 to (+) wire of Alarm devices
- Connect GND port to (-) wire of Alarm devices
Figure: Door Lock, Al
arm Device Connection
Caution: You need to connect the diode ( 1N4001 ~ 1N4007 or Similar) when connecting external devices to
relay.
5.4.4 Reader Connections
Proximity Reader Connection
- Connect (+) wire of the Proximity Reader to DC+12V of Reader port
- Connect (-) wire of the Proximity Reader to GND of Reader port
- Connect Data-0 wire of the Proximity Reader to D0 of Reader Port
- Connect Data-1 wire of the Proximity Reader to D1 of Reader Port
Compatible Readers
:
- iCON100:
Standard 26bit Wiegand Format Proximity Readers, Standard 26bit W 8bit Burst
Format Proximity and Keypad Readers.
- iCON100SR:
Standard 34bit Wiegand Format Proximity Readers, Standard 34bit Wiegand + 8bit
Burst Format Proximity and Keypad Readers.
Figure: Reader Connection