5.

 

Internal Specifications  

Zeus has an internal heater with a 4-temperature sensor monitored by a Micro-Controller Unit (MCU). 
When Zeus is off and the ambient temperature is below -20°C, the MCU will hold the power button, 
activate the heater, and heat the device until it is above -20 °C. A powered-on MCU will monitor for 
high temperatures. When the temperature is over 40 °C, the MCU will start the FANs of the system. 
 

WARNING: 

Zeus has no internal serviceable components and opening it voids the warranty. 

 

Summary of Contents for Zeus

Page 1: ...Street Cypress CA 90630 4720 Tel 714 761 6368 Fax 714 761 8880 www idtechproducts com support idtechproducts com Zeus All in One Outdoor Industrial Touchscreen Computer User Manual 80168500 001 D Quick Start 31 August 2019 ...

Page 2: ...efective equipment which does not conform to the requirements of sales is to have such equipment replaced or repaired by ID TECH For limited warranty service during the warranty period please contact ID TECH to obtain a Return Material Authorization RMA number instructions for returning the product THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOS...

Page 3: ... subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation Important Changes or modifications to this product not authorized by manufacturer could void the EMC compliance and negate your authority to operate the product This device and its antennas must not b...

Page 4: ...Zeus All In One User Manual Page 4 Table of Contents 1 Introduction 5 2 Features 5 3 System Recovery 5 4 Specifications 6 5 Internal Specifications 7 ...

Page 5: ...IDDD 21520 Account Password No Password Windows Update Preferences Automatic updated turned off Time Zone Date Time UTC 08 00 Pacific Time All parameters can be changed through the Control Panel 1 To change the Computer Name click Control Panel System 2 Find Computer Name click Domain Workgroup Settings Change Settings 3 Under the Computer Name tab type the new computer name in the Computer Descri...

Page 6: ... Memory Storage 2GB RAM 4GB maximum 60GB Solid State Drive Webcam 2 0 megapixel I O USB 2 0 x3 RS232 COM Port 1 Gigabit Ethernet Port Dual Band WiFi Bluetooth 4 0 Environmental Operating Temperature 40 F to 140 F 40 C to 60 C with built in heater Humidity 5 90 non condensing Reliability Warranty One year Optional extended warranty up to four years Approvals FCC CE UL Mechanical Dimension L x W x H...

Page 7: ...Zeus is off and the ambient temperature is below 20 C the MCU will hold the power button activate the heater and heat the device until it is above 20 C A powered on MCU will monitor for high temperatures When the temperature is over 40 C the MCU will start the FANs of the system WARNING Zeus has no internal serviceable components and opening it voids the warranty ...

Reviews: