![IDTECH ViVOpay VP6300 User Manual Download Page 20](http://html.mh-extra.com/html/idtech/vivopay-vp6300/vivopay-vp6300_user-manual_618768020.webp)
ViVOpay VP6300 User Manual
20
6.
Firmware Upgrade
The VP6300 can have its firmware upgraded in the field using either serial or USB interfaces.
Preparation
To update the new firmware you will need:
•
PC with available serial or USB port
•
VP6300 with a serial data cable or a USB cable attached
•
Firmware files (including Boot Loader files) for the desired firmware
•
Software (for the PC) that will upload the firmware files to the VP6300
6.2
Uploading Firmware for RS232 or USB
1.
Move firmware files (*.fm) and bootloader .exe files into into the same folder.
2.
Check and confirm device is correctly connected to the power source and RS‐232/USB
connection.
3.
If RS232 is the interface choice, then please close all software that is using RS‐232
communication.
4.
Run the bootloader utility, choosing communication type and parameters according to the
connection interface.
For serial interface, choose “COM” and Baud Rate of 19200 (default).
For USB interface, choose “HID” and verify VID displaying 0ACD.
5.
Click the “Load” button ‐ the firmware will be loaded into the device. When “Firmware
successfully downloaded” appears on the utility, then the firmware has been successfully
installed. The Utility may be closed at that time.
Serial Interface: