Copyright © 2019, International Technologies & Systems Corp. All rights reserved.
Page 18 of 24
The process is:
Step2.1 Press Default Loading Key Password once and device will beep
Complete Tone
.
(If the first numeric key is pressed, Device will stop Always beeps).
Step2.2 Press New Password first times, and device will beep
Complete Tone
. (New
Password need not be same as Default Loading Key Password.)
Step2.3 Press New Password second time, and device will beep
Complete Tone
.
If the password is modified successfully, Device beeps
Complete Tone
and the New
Password is a User Loading Key Password.
If another Password is Default Loading Key Password, beeper will beep always. Then User need
not Re-Power on device (unplugging device) and can do above Process (Step2.1 ~ Step 2.3) to
modify another Default Password.
If 2 Password all be modified to User Activation Password; device quits “Want Loading Key
State”.
Interval limits:
The Interval between Password1 and Password2 is 20 seconds.
The Interval between the two keys of a password is 10 seconds.
Any key will have a short tone to be the acknowledgement tone.
Step3. Press User Activation Key Password
If the User presses 2 User Loading Key Passwords
A User Password is pressed correctly, Device beeps
Normal Tone
Another User Password is pressed correctly, Device beeps
Normal Tone
Device confirms 2 User Passwords correct:
If Device is not Fixed and
IN Removal State
: Device beeps
Device is Removal Tone
and
quit “Want Fix / Removal Device State”.
If Device is Fixed and
IN Removal State
: Device beeps
Complete Tone
,
Active Fix
Device
successfully, save 2 Records for Active Fixed Device, and quit “Want Fix /
Removal Device State”.
If Device is Fixed and
IN Fixed State
: Device beeps
Device IN Fixed State Tone
and quit
“Want Fix / Removal Device State”.
If the User presses at least an incorrect User Activation Password, Device beeps
Invalid Tone
and the User can presses again.
If the User presses incorrect User Activation Password 3 times, Device beeps
Invalid Tone
and
Suspend 3 Minutes. After Device finished suspend, Device quit “Want Fix / Removal Device
State”.
Interval:
The Interval between Password1 and Password2 is 2 Minutes.
The Interval between the two keys of a password is 10 Seconds.
7.5
Activate Removal of Device (Legally, via Password)
Step1. Power On device, after device beeps
Normal Tone
, please press
Cancel
,
Back
,
Enter
,
Help
,
Cancel
, and
Help
(6 keys). The interval between the two keys need be at most 5 seconds.
If Log of Fix and Removal is full, Device Beeps
Invalid Tone
and quit “Want Fix / Removal
Device State”.
If there is at least a Default Activation Password in device.